Operating the Printer
Continued 3.Received Data and Software Errors
Description
LCD message
LED
B.Z. C.f. E-Code
Recovery
Image print error occurred. Specified number is not yet registered.
Image print err.
unregistered nr
ERROR ON
S A-7154
Check the host data.
Image print error occurred. The vertical direction size of an image
is illegal.
Image print err.
vert. dir size
ERROR ON
S A-7159
Check the LOGO data.
Images print error occurred. The vertical direction size of an image
is illegal..
Image print err.
vert. dots ill.
ERROR ON
S A-7158
Check the LOGO data.
Image print error occurred. Vertical coordinates of the image
illegal.
Image print err.
vertical coor.
ERROR ON
S A-7155
Check the host data.
Image print error occurred. Vertical direction size exceeds 612 dots
during editing bit map image of character print data on a
document.
Image print err.
vertical size
ERROR ON S A-7150
Check the host data.
Image print error on vertical size occurred.
Image print err.
vertical size
-- -
S -
Check the host data.
Incorrect field exists.
Incorrect field:
xx
(xx: field number)
-- -
S -
Check the ticketing data.
During non-control mode of SCN, the SCN read command is
received.
In non SCN mode
SCN command rec.
ERROR ON S A-7010
Check the host data.
Firmware internal error occurred.
Invalid command
ERROR ON S A-7002
Call the maintenance personnel.
Invalid stock control number was read.
Invalid stock
ctrl nr read
-- -
S -
Check the ticket.
MS encode data format error (verify error).
MS encode data
format error
ERROR ON O/H A-7110
Check the magnetic stripe or clean the magnetic head.
MS encode horizontal format error (parity check error).
MS encode horiz.
format error
ERROR ON O/H A-7112
Check the magnetic stripe or clean the magnetic head.
No Background (template) data available. (AEA response)
No Background
-- -
S -
Check host data.
No magnetic position defined in PECTAB table when the steering
command is defined "check-in", "boarding" or "revalidation" in the
table.
No mag pos
defined:xx
(xx: element Number)
-- -
S -
Check host data.
No medium is available in escape path.
No medium
Available
ERROR ON S A-7005
Check the medium is in escape path.
No separator available.
No separator
-- -
S -
Check host data.
Object in background (ten plates) was not found out.
Object missing:
-- -
S -
Check host data.
PECTAB memory is full.
PECTAB memory
full
-- -
S -
Cancel unnecessary PECTAB data.
PECTAB is not available.
PECTAB not
available :xx
(xx: PECTAB number)
-- -
S -
Check the host data.
The ticketing data is too large.
Print buffer
overflow (INT.)
-- -
S -
Check the ticketing data.
Program down line loading data is wrong.
Program load
fault
-- -
S
E-
3050-60 Check the down line loading data.
Registration area full. No empty registration area for an
Image data registration command (quantity and size).
Registration area
full
ERROR ON S A-7003
Cancel unnecessary PECTAB data.
Out of sequence in check-in or revalidation mode.
Sequence check
error
-- -
S -
Check the host data.
Firmware internal error occurred.
Sequence error
ERROR ON S A-7007
Call maintenance personnel.
Too many coupons are in one job.
Too many coupons
in one job
-- -
S -
Check the host data.
Firmware internal error occurred.
Undefined command
ERROR ON S A-7001
Call maintenance personnel.
Wrong document type selected.
Wrong document
type:
-- -
S -
Check the host data.
Wrong element used.
Wrong element
-- -
S -
Check the host data.
10
Summary of Contents for 9811 ATB