En-4
4. ELECTRICAL REQUIREMENT
The indoor unit is powered from the outdoor unit or branch box. Do not power indoor unit
from separate power source.
WARNING
Refer to local codes for acceptable cable type.
5. SELECTING THE MOUNTING POSITION
Decide the mounting position with the customer as follows:
5.1. Indoor unit
(1) Install the indoor unit level on a strong wall which is not subject to vibration.
(2) The inlet and outlet ports should not be obstructed: the air should be able to blow all
over the room.
(3) Install the unit a dedicated electrical branch circuit.
(4) Do not install the unit where it will be exposed to direct sunlight.
(5) Install the unit where connection to the outdoor unit or branch box is easy.
(6) Install the unit where the drain pipe can be easily installed.
(7) Take servicing, etc. into consideration and leave the spaces shown in “6.1. Installation
dimensions”. Also install the unit where the
fi
lter can be removed.
Correct initial installation location is important because it is dif
fi
cult to move unit after it is
installed.
WARNING
Select installation locations that can properly support the weight of the indoor. Install the
units securely so that they do not topple or fall.
CAUTION
Do not install the unit in the following areas:
• Area with high salt content, such as at the seaside. It will deteriorate metal parts, causing the parts
to fail or the unit to leak water.
• Area
fi
lled with mineral oil or containing a large amount of splashed oil or steam, such as a
kitchen.
It will deteriorate plastic parts, causing the parts to fail or the unit to leak water.
• Area that generates substances that adversely affect the equipment, such as sulfuric gas, chlorine
gas, acid, or alkali.
It will cause the copper pipes and brazed joints to corrode, which can cause refrigerant leakage.
• Area that can cause combustible gas to leak, contains suspended carbon
fi
bers or
fl
ammable
dust, or volatile in
fl
ammables such as paint thinner or gasoline.
• If gas leaks and settles around the unit, it can cause a
fi
re.
• Area where animals may urinate on the unit or ammonia may be generated.
Do not use the unit for special purposes, such as storing food, raising animals, growing
plants, or preserving precision devices or art objects.
It can degrade the quality of the preserved or stored objects.
Do not install where there is the danger of combustible gas leakage.
Do not install the unit near a source of heat, steam, or
fl
ammable gas.
Install the unit where drainage does not cause any trouble.
Install the indoor unit, outdoor unit, branch box, power supply cable, transmission cable,
and remote control cable at least 1 m (40 in.) away from a television or radio receivers.
The purpose of this is to prevent TV reception interference or radio noise.
(Even if they are installed more than 1 m (40 in.) apart, you could still receive noise
under some signal conditions.)
If children under 10 years old may approach the unit, take preventive measures so that
they cannot reach the unit.
Install the indoor unit on the wall where the height from the
fl
oors more than 1.8 m (70 in.).
6. INSTALLATION WORK
6.1. Installation dimensions
110 mm (4-11/32 in.)
or over **
1.5 m (59-1/16 in.)
or over
Remote
controller
Remote controller
holder
Tapping screw
(small)
1.8 m (70-7/8 in.)
or over
(Wall cap)
120 mm (4-23/32 in.) or over *
Wall hook
bracket
110 mm (4-11/32 in.) or over **
* The distance between the wall hook bracket and the ceiling
should be 120 mm (4-23/32 in.) or more.
** The side next to the sidewall must follow the size indicated in the
figure.
6.2. Indoor unit piping direction
The piping can be connected in the 6 directions indicated in the following.
When the piping is connected in direction (2) , (3) , (4) or (5) , cut along the piping groove
in the side of the under cover with a hacksaw.
(Rear)
(2) Right
outlet
(5) Left
outlet
(6) Left rear
outlet
(3) Right bottom outlet
(1) Right rear outlet
(4) Left bottom outlet
6.3. Under cover removal
(1) Remove the screw caps and screws from the
under cover (in each of 3 places).
(2) Lift up the central part of the under cover.
(3) Release the tabs by pressing on the side of the
under cover (in 2 places on the side).
(4) Remove the under cover while turning it.
(1)
(1)
(1)
Under cover
Screw cap
Screw
(4)
(4)
(3)
(2)
6.4. Under cover installation
(1) Push the tabs on the side of the under cover into
the base (in 2 places on the side).
(2) Press in the top parts of the triangle markings on
the under cover (in 2 places).
(3) Attach the screws (in 3 places).
(4) Attach the screw caps (in 3 places).
(1)
(1)
(1)
(2)
(2)
9319357041_IM.indb 4
9319357041_IM.indb 4
11/30/2011 1:32:14 PM
11/30/2011 1:32:14 PM
Summary of Contents for 9319357041