Table 6 (Cont.)
Specification In 3GPP 38.113
Phenomenon
Application
Reference Standard
Detail
Specification
Criteria
Electrostatic discharge
Enclosure
IEC 61000-4-2
Electric Discharge
B
Fast transients common mode
Signal, telecommunications and
control ports, DC power input
ports
IEC 61000-4-4
Fast Transients
Common Mode
B
RF common mode 0, 15…80 MHz
Signal, telecommunications and
control ports, DC power input
ports
IEC 61000-4-6
RF Common Mode
A
Surges, common and differential
mode
AC power input ports,
telecommunications port
IEC 61000-4-5
Resistability of
Lightning
B
Radiated Immunity
Test Standard
3GPP 38.113
IEC 61000-4-3 Level 3
Test mode
Traffic mode, excludes receiver exclusion band.
80…6000 MHz
3 V/m, AM 80%
Performance Criteria
A
Electric Discharge
Test standard
3GPP 38.113
IEC 61000-4-2
Contact discharge
±4 kV
Air discharge
±8 kV
Performance Criteria
B
Fast Transients Common Mode
Test standard
3GPP 38.113
IEC 61000-4-4
0.5 kV
Performance criteria
B
Injected port
Power consistency, RET consistency
RU Hardware Feature
RU Specifications
26
Release 1.0
·
Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only