A26361-K619-Z100-1-7619
37
Technical data
Electrical data
Regulations complied with:
IEC 60950, EN 60950
UL 1950
CSA 22.2 No.950
Protection class:
I
Rated voltage range: (selectable)
100 V - 125 V / 200 V - 240 V
Frequency:
50 Hz - 60 Hz
Max. rated current
•
System unit with monitor socket:
•
Monitor socket (output)
100 V -125 V/4,0 A
200 V -240 V/2,0 A
100 V -125 V/3 A
200 V -240 V/1,5 A
Typical power draw in operation:
Power draw in the 'ready' status
< 45 W *)
< 5 W *)
Noise emission:
Sound power level (L
WAd
) < 30 dB (A) *)
*)
These values only apply for a JETSON with the configuration below.
Processor (512 Kbyte cache):
Main memory:
Hard disk drive:
CD/DVD-ROM drive
Pentium III Processor at 733 MHz
128 Mbyte
20 Gbyte
24fold
Dimensions and weight
Width/depth/height:
368 mm/268 mm/ 99 mm
Weight
approx. 5 kg
Environmental conditions
Environment class (3K2)
Environment class (2K2)
DIN IEC 721 part 3-3
DIN IEC 721 part 3-2
Temperature:
•
Operating (3K2)
•
Transport (2K2)
15 °C .... 35 °C
-25 °C .... 60 °C
Condensation in operating must be avoided.
Clearance required to ensure adequate ventilation:
•
left-hand side
•
right-hand side
min. 200 mm
min. 200 mm
In the vertical operating position (only with stand-up feet) the air intake and exhaust spaces at the
top must be at least 7 in (200 mm).