D2300 (RX200 S3)
Technical Manual
9
Important notes
Notes on safety
Modules with electrostatic-sensitive components
Boards with electrostatic sensitive devices (ESD) are marked with the following
label:
Figure 1: ESD label
You must follow the instructions below when handling modules containing
electrostatic-sensitive components
●
You must always discharge yourself of static charges (e.g. by touching a
grounded object) before touching the components.
●
The equipment and tools you use must be free of static charges.
●
Remove the power plug from the power socket before inserting or removing
boards containing ESDs.
●
Always hold boards with ESDs by theit edges.
●
Do not touch any exposed pins or conductors on a component.
●
Use a grounding cable designed for this purpose to connect yourself to the
system unit as you install/deinstall the board.
●
Place all components on a static-free surface.
I
You will find a detailed description for handling ESD components in the
relevant European or international standards (EN 61340-5-1,
ANSI/ESD S20.20).