2
Safety Pr
ecautions
WARNING
Never attempt to disassemble, repair or modify.
Always seek help from a qualified technician. Otherwise, there may be fire, electric shock or
abnormal conditions.
Do not use in regions where the power voltage exceeds 220V/230V/240V AC.
Otherwise, there may be fire hazards or electric shock.
The cooker hood is intended to be installed over a hob with up to four hob elements or
burners.
Disassembly,
repair, or
modification
prohibition
Prohibition
on use
Less than
4 burners
Electric wiring shall be carried out properly by professional technician or personnel.
Incorrect wiring may cause electric leakage or fire hazards.
Caution
during
assembly
Read the following safety precautions before installation and operation, and use the cooker hood properly
and securely.
These safety precautions are for correct operation of the product, preventing any harm or damage to
yourself or others. These safety precautions are classified into 2 categories (“WARNING” and “CAUTION”)
depending on their hazard and severity. Please pay attention and strictly observe these safety precautions
as they are crucial to safety.
Safety Precautions
Be sure to disconnect the power plug from the outlet, or switch off the breaker during
maintenance. Also, never handle the power plug or breaker with wet hands.
Otherwise, there may be electric shock or physical injury.
Disconnection
of the power
plug
The power plug shall be cleaned regularly to prevent dust accumulation.
Otherwise, there may be fire hazards or electric shock.
Never spray water on any electric parts.
Otherwise, there may be fire hazards or electric shock.
Dust removal
Water
spraying
prohibition
Installation work should be performed by a minimum of 2 persons.
The weight of the cooker hood is about 15kg (FR-FS2270VP), 17kg (FR-FS2290VP),
18kg (FR-FS2290RP).
Caution
during
installation
Breakers shall be incorporated in the fixed wiring to ensure all-pole disconnection from
the main power source.
Caution
during
installation
WARNING
CAUTION
Alerts possible risk of
serious injury
, if not observed.
Alerts possible risk of
injury
or
physical damage
, if not observed.
In case of a gas leak, do not switch on the cooker hood.
Otherwise, it may result in a gas explosion.
Operation
prohibition
The cooker hood shall be installed at a place with sufficient ventilation.
When using a natural exhaust type stove, poor ventilation may result in carbon monoxide
poisoning.
Attention to
ventilation
The air shall not be discharged into hot flues that are used for discharging fumes
generated from burning gas or other fuels (not applicable to cooker hoods that can
discharge the air back into the room).
Strict
implementation