EN-5
Installation and Connection
Installation
Use the screw holes on the base to secure the camera to a mount or other surface.
4
WARNING
Attach the product securely to a surface that can safely bear the combined weight of the camera and associated hard-
ware. Do not mount the camera in unstable locations or locations subject to frequent vibration or attach it to weak
materials such as drywall, ALC (autoclaved lightweight concrete), concrete blocks, or plywood. Injury could result
should the product fall from its mounting.
4
CAUTIONS
• Use ¼
ʺ
, UNC 20 thread screws with a thread engagement length of 6.5 to 10 mm.
• Install the camera base down.
A handle can be attached using the screws on top of the camera.
4
CAUTIONS
• Use M4 screws with a thread engagement length of at least 4 mm and a protru-
sion of no more than 6 mm.
• Do not use the screw holes on top of the camera for any other purpose.
Screw Hole Specifi cations
Screw Hole Specifi cations
The specifi cations for the screw holes on the top and base of the camera are as follows:
Type
Quantity
Depth
Tightening torque
Top
M4
2
Pass through (threaded depth 4 mm)
80–100 N•cm
Base
¼
ʺ
, UNC 20 thread
15
10 mm
240–300 N•cm
Handle
thickness
4 mm
Max. 6 mm