OPERATION IN EACH SITE SITUATION
6-1-2 With 1 surveyor
If the PL-G MAX will be used by just 1 person,
please follow these instructions:
①
Ensure there is enough battery power in the Transmitter.
②
Confirm that the Transmitter is set to IND
(Induction Mode)
③
Choose the frequency of Transmitter:
Either 83KHz or 27kHz may be used useful to confirm
the location of a pipeline.
④
Adjust the output power with the Output Power Control
Key between levels 2 and 5.
The Power Level should be chosen in accordance with
site conditions.
⑤
Place the Transmitter on the ground where the pipeline is
presumed to be buried.
⑥
Turn on the Receiver and select the same
frequency as the Transmitter (83kHz or 27kHz).
⑦
Have approximately 5 meters or more between the
Transmitter and the Receiver.
The Transmitter is must face the Receiver
as shown by the figure on the left
⑧
Locate the point where the Receiver displays the
maximum Bar Graph and Numerical Value as shown by
the left figures
(A) (B) (C)
. Those points are the location
of the buried pipeline.
The Transmitter is required to be placed on the line shown
by the figure
(A) (B) (C)
.
NOTE : Ensure the transmitter is oriented correctly with the
pipeline.