OPERATION OF RECEIVER
5-1 Operational procedure
5-1-1
Measurement Mod
NOTE: Pull-up depth measurement is the most precise
5-1-2
Operational Procedure of Receiver
(a)
Push the Power Switch Key
(b)
Choose one of above modes
(c)
Choose one frequency
NOTE : Use the same frequency for both the transmitter and receiver.
About 5 meters away from the transmitter, keep the
direction and angle of the antenna perpendicular to
the pipeline as illustrated in next page, and move
sideways to pinpoint the pipeline.
Point 1. Operate the gain control switch to facilitate
the measurement.
Point 2. For night operation, press the backlight switch to illuminate
the LCD display.
Point 3. Press the volume switch until the volume is
appropriate for operation.
Large
→
Medium
→
Small
→
OFF
*The vibration function is turned ON/OFF by long press.
Pull-Up
Horizontal
Maximum Mode
It is useful to locate the position of
pipeline correctly.
Minimum Mode
It is used to go faster by locating the
pipeline roughly.
Bar Mode
It is utilized to locate the pipeline over
a longer distance.
Sonde Mode
By use of the Sonde (Probe), the
non-metallic pipeline such as the
Plastic Pipeline can be located.
Depth Measurement
MODE
EXPLANATION
(a)
(c)
(b)
Point 1
Point 2
Point 3
Continuous
Depth
Mode
To locate the position of
pipeline correctly.
To grasp the change of depth
of the pipeline.
To locate the pipeline over a
longer distance
By use of Sonde (probe),non-
metallic pipeline can be located.