54
FinePix4800Zoom(U/E/EG) SERVICE GUIDE
Initial Adjustment
Page
Add Purpose
Name
Function (Contents)
value
value
5.List of Adjustment Addresses and Data
4
A7h
E_FJX_ADR8
FUJIX management address 8
00h
4
A8h
E_FJX_ADR9
FUJIX management address 9
00h
4
A9h
E_FJX_ADR10
FUJIX management address 10
00h
4
AAh
E_FJX_ADR11
FUJIX management address 11
00h
4
ABh
E_FJX_ADR12
FUJIX management address 12
00h
4
ACh
00h
4
ADh
E_JIG_STRB
For flash jig (0: No flash, /1: Jig light adjustment, 2/Automatic light adjustment)
00h
4
AEh
E_ZPOS
LANC zoom drive destination (drive from DATA SCREEN)
00h
4
AFh
E_ZPOSMON
Zoom position monitor (0: Telescopic, 1: Telescopic transition, 2: TELE, ~, 9: WIDE)
00h
4
B0h
E_LAST_PWROFF Last power OFF conditions
00h
4
B1h
E_PRE_PWROFF Power OFF conditions for one before last
00h
4
B2h
E_YCPRO_SEL
YCPRO/S2 FOCUS hold excitation select
3h
4
B3h
E_FNOCCD
Data indicating rate of reduction in CCD sensitivity data (EV value for difference between minimum aperture and open, EVx10)
00h
4
B4h
E_3200K_R
Data indicating WB adjustment data (3200K R pixel level)
00h
O
4
B5h
E_3200K_G
Data indicating WB adjustment data (3200K G pixel level)
00h
O
4
B6h
E_3200K_B
Data indicating WB adjustment data (3200K B pixel level)
00h
O
4
B7h
E_6100K_R
Data indicating WB adjustment data (6100K R pixel level)
00h
O
4
B8h
E_6100K_G
Data indicating WB adjustment data (6100K G pixel level)
00h
O
4
B9h
E_6100K_B
Data indicating WB adjustment data (6100K B pixel level)
00h
O
4
BAh
E_CARD_STATUS Card status monitor
00h
4
BBh
E_TG_LD_CHK
TG PROGRAM READ CHECK(1:OK,FF:NG)
00h
4
BCh
00h
4
BDh
E_ERROR_INFO
Error information flag (0: No display, 1: Display)
00h
4
BEh
E_TEST_COMC
External communications channel (0: Asynchronous/1: USB) Note: Change the initial value to USB after USB release.
00h
4
BFh
00h
4
C0h
00h
4
C1h SG management
E_SG10
For SG
00h
4
C2h
E_SG11
For SG
00h
4
C3h
E_SG12
For SG
00h
4
C4h
Basic notification data
E_OFD_B
OFD bottom voltage
00h
O
4
C5h
E_OFD_T
OFD top voltage
00h
O
4
C6h
E_TEST_QLT
QLT value for fixed length examination
00h
4
C7h
E_TEST_IDX_H
IDX value (high) for fixed length examination
0Bh
4
C8h
E_TEST_IDX_L
IDX value (low) for fixed length examination
1Ch
4
C9h
E_TEST_TGV_H
TGV value (high) for fixed length examination
03h
4
CAh
E_TEST_TGV_M
TGV value (mid) for fixed length examination
A9h
4
CBh
E_TEST_TGV_L
TGV value (low) for fixed length examination
80h
4
CCh
E_TEST_LIM
LIM value for fixed length examination
FAh
4
CDh
E_LA2G_A
WBG <adjustment value> at lamp 2 auto
24h
O
4
CEh
E_LA2R_A
WBR <adjustment value> at lamp 2 auto
2Ch
O
4
CFh
E_LA2B_A
WBB <adjustment value> at lamp 2 auto
38h
O
4
D0h
E_LA2MINRG
Lamp 2 detection frame X1
78h
4
D1h
E_LA2MAXRG
Lamp 2 detection frame X
C8h
4
D2h
E_LA2MINBG
Lamp 2 detection frame Y1
14h
4
D3h
E_LA2MAXBG
Lamp 2 detection frame Y
46h
4
D4h
E_L2LMINRG
Fluorescent lamp daylight color low temperature detection frame X1
35h
4
D5h
E_L2LMAXRG
Fluorescent lamp daylight color low temperature detection frame X2
46h
4
D6h
E_L2LMINBG
Fluorescent lamp daylight color low temperature detection frame Y1
49h
4
D7h
E_L2LMAXBG
Fluorescent lamp daylight color low temperature detection frame Y2
5Ah
4
D8h
E_IN_EXW0
Indoor-like white membership 1
0Ah
4
D9h
E_IN_EXW1
Indoor-like white membership 2
0Dh
4
DAh
E_L2LG_A
WBG <adjustment value> at fluorescent lamp daylight white color low color temperature auto
24h
O
4
DBh
E_L2LR_A
WBR <adjustment value> at fluorescent lamp daylight white color low color temperature auto
3Eh
O
4
DCh
E_L2LB_A
WBB <adjustment value> at fluorescent lamp daylight white color low color temperature auto
33h
O