5
Wiring
FuelCloud piggybacks AC power off of the input.
Your wiring configuration will depend on whether
the pump runs on AC or DC power.
AC power has a 100-240VAC power range. For power input,
attach the appropriate wires (L, N, G) to the designated terminals
on the top bank of terminals on the left-hand side of the
CloudBox circuit board.
For power output, attach the appropriate wires to the designated
terminal on the bottom bank of terminals on the left-hand side of
the CloudBox circuit board.
DC power has a 8-50VDC power range. For power input, attach
the appropriate wires (DC+ & DC-) to the designated terminals
on the top bank of terminals on the left-hand side of the
CloudBox circuit board.
For power output, attach the appropriate wires to the designated
terminals on the bottom bank of terminals on the left-hand side
of the CloudBox circuit board.
In addition to input and output power, 8-50VDC is needed to
power the hardware. Note: A Class 2 power source is needed to
power the DC portion of the hardware.
AC:
DC:
Summary of Contents for CLOUDBOX
Page 1: ...CLOUDBOX Quick Start Guide ...
Page 7: ...DC INPUT INPUT OUTPUT OUTPUT AC CLASS 2 WIRING TERMINAL DC DC ...