Kabeldurchführung
PG11-Verschraubung mit Zugentlastung
Anzeige
optionales LCD-Display mit Hintergrundbeleuchtung. (an/aus/auto bei 0-10 V Ver-
sion; bei 4-20 mA über DBL-Klemme)
Material
Anlegeblock: Aluminium
Abmessungen
Gehäuse: L 89 x B 80 x H 47 mm, Anlegeblock: L 25 x B 54 x H 15 mm
Schutzart
Gehäuse/Elektronik: IP65, Sensor: IP30
Schutzklasse
III
Arbeitsbereich r.F.
0...98% r.F. in schadstofffreier, nicht kondensierender Luft
Betriebstemperatur
Fühler: -20...+80°C, Elektronik: 0...+50°C
Lagertemperatur
-20...+50°C
Montage
Spannband, Bandbreite 9 mm, Spannbereich 50-110 mm, Stahl verzinkt (im Lie-
ferumfang enthalten)
Zulassungen
CE, EAC, RoHS
Technical Specifications
Measurement range r.H.
0-100% r.H.
Measurement range abs. humidity
0-50 g/m³, 0-80 g/m³ (calculated) selectable by DIP switch
Measurement range air fuel ratio
0-50 g/kg, 0-80 g/kg (calculated) selectable by DIP switch
Measurement range dew point
-20...+50°C DP, -20...+80°C DP, 0...+50°C DP (calculated) selectable by DIP switch
Measurement range temp.
-20...+80°C
Scales
-30...+70°C, -20...+80°C, 0...+50°C, 0...+100°C selectable by DIP switch
Accuracy humidity
±3% r.H. (30-70% r.H., else ±5% r.H., at 20°C)
Accuracy temperature
±0,5 K
Temperature dependency
±0,02% r.H. / K (voltage output), ±0,04% r.H. / K (current version); ±0,05°C / 10 K
(voltage version), ±0,07°C / 10 K (current output)
Long term stability
±1%/year
Sensor
Combined electronic humidity and temperature sensor
Sensor protection
sinter filter, sensor mounted inside the contact block
Flow rate
< 2 m/s
Supply voltage analog 0-10 V
24 V AC/DC (±5%)
Supply voltage analog 4-20 mA
15...36 V DC (Ubmin = 15 V + RLoad*0,02A)
Current consumption at 0-10 V
typ. 10 mA, 30 mA peak current consumption for 50 ms at switching moment at
option relay
Current consumption at 4-20 mA
max. 20 mA / output, 40 mA peak current consumption for 50 ms at switching
moment at option relay
Analogue output 0-10 V
3-wire connection, load current < 0,1 mA
Analogue output 4-20 mA
2-wire connection (transmitter), max. RLoad(Ohm) = (+Ub - 15 V) / 0,02 A
Alarm output
1 x potential-free change-over contact, 48 V, 1 A
Switching Hysteresis Relay
2% of the selected scaling (without display), 0,5...5% of the selected scaling ad-
justable (with display)
Electrical connection
screw terminals max. 1,5 mm²
Housing
Polycarbonate PC UL 94 V0 with hinge locks, color signal white similar to RAL 9003
Cable gland
PG11 high-strength cable gland with strain relief
Display
optional LCD display with backlight (on/off/auto at 0-10 V version, at 4-20 mA
version via DBL terminal)
Material
Contacting block: aluminium
Dimensions
Housing: L 89 x W 80 x H 47 mm, Contacting block: L 25 x W 54 x H 15 mm,
Protection type
Housing/electronic: IP65, Sensor: IP30
Protection class
III
Working range r.H.
0...98% r.H. in contaminant-free, non-condensing air
Working temperature
Probe: -20...+80°C, Electronic: 0...+50°C
Storage temperature
-20...+50°C
Installation
clamping band, band width 9 mm, chucking capacity 50-110 mm, galvanized steel
(in scope of delivery)
Approvals
CE, EAC, RoHS
Measurement range dew point
-20...+50°C DP, -20...+80°C DP, 0...+50°C DP (calculated) selectable by DIP switch