Always make a pre-operation inspection before you start the engine. You

may prevent an accident or equipment damage.

Place the generator at least m away from buildings or other equipment during operation.
Operate the generator on a level surface. If the generator is tiled, fuel spillage may result.

Know how to stop the generator quickly and understand operation of all the controls.Never permit

anyone to operate the generator without proper instructions.

Keep children and pets away from the generator when it is in operation.
Keep away from rotating parts while the generator is running.

The generator is a potential source of electrical shocks when misused; do not operate with wet

hands.

Do not operate the generator in rain or snow and do not let it get wet.

- The power generator is a mains replacement that generates electrical power for supply to a mobile

distribution system.

- The power generator must be operated outdoors within the prescribed voltage, output and rated
speed limits (see type plate).
- The power generator must not be connected to other electrical supply systems or electric generation
systems (e.g. other power generators).
- The power generator may not be used in environments where there is a risk of explosion.
- The power generator may not be used in environments where there is a risk of fire.
- The power generator must be operated in accordance with the conditions set out in the technical
documentation.
- All improper use of the power generator including all uses not described in these instructions will
constitute unauthorized incorrect usage for which the manufacturer is not legally liable.
- Operation in environments where there is a risk of explosion and fire.
- Operation in enclosed areas and under direct exposure to rain or snowfall.
- Operation without the requisite safety precautions and connected to existing supply network
systems.
- Spraying with high-pressure cleaners or fire extinguishing equipment.
- Non-compliance with regular servicing requirements.
- Failure to carry out measurements and checks for early detection of defects.
- Know and apply the Prevention of Injury regulations and the safety instructions for the power
generator.
- Understand and be able to practically implement the technical documentation.
- The operator must know the functions of, and be able to use, the components of the power generator.
- The operator must wear the appropriate personal safety equipment.
- The labelling on the electrical generator must be complete and maintained in a readable condition.
- Constructive changes may not be carried out on the electrical generator.
- The rated speed of the motor has been set during manufacture and may not be changed.
- The operating safety and correct functioning must be checked before and after each use.
- No naked flames, lights or spark-emitting appliances may be used within the hazard area of the
power generator.
- Smoking within the hazard area of the power generator is strictly forbidden.
- During operation, the power generator must be protected from dirt and foreign matter.
- The power generator may only be transported when cold.
- The power generator may only be lifted using the carry handles intended for this purpose.
- The electrical safety must be checked before each operational use.
- The appliance may not be covered. The air intake may not be blocked or obstructed.
- When starting, the load may not be connected.
- Only certified and approved cables may be used for the wired network.
- The power drawn may not exceed the maximum rated power.

www.fubag.ru

O

m

perator's

anual

WARNING!

Summary of Contents for WHS 190 DC

Page 1: ...www fubag ru WHS 190 DC Operator s Manual Welding power station WHS 210 DC FUBAG 495 641 31 31 info fubag ru www fubag ru...

Page 2: ...on and remains hot for a while after stopping the engine Be careful not to touch the muffler while it is hot Let the engine cool before storing the generator indoors The engine exhaust system will be...

Page 3: ...sk of explosion and fire Operation in enclosed areas and under direct exposure to rain or snowfall Operation without the requisite safety precautions and connected to existing supply network systems S...

Page 4: ...secured by your operation Prevent the sparks and spatter from harming your body Under no circumstance allow any part of your body to touch the welder s output bipolarity torch and work piece Fumes an...

Page 5: ...W 1 O 1 O 1 F 1 C 1 R 1 A Starting key Digital display ircuit breaker ocket 220V uel tank cap uel gauge urrent regulation knob Indicator lamp elder teminals 0 il drain plug 1 il filler cap 2 uel valve...

Page 6: ...additional 10 C and or approximately 1 for every additional 100m in altitude Specifications Model WHS 190 DC WHS 210 DC Rated voltage V 230 230 Rated frequency Hz 50 50 Max output kWA 4 5 5 Rated out...

Page 7: ...out a dipstick is available if necessary on the other side of the engine Check the level and top up if necessary If it is necessary Using a funnel fill the engine oil sump right up to the top of the f...

Page 8: ...When the engine has started gradually open the choke If the engine has not started repeat the procedure until the engine starts while gradually opening the choke Note 4 Pull the starter handle slowly...

Page 9: ...cable connect the welding cables to the welder s DC terminals Start the engine run at no load to warm up fully Set the current adjust knob to the proper current level 2 3 High altitude operation At h...

Page 10: ...arried out oftener than under usual operating conditions as they are considered to be rough The maintenance interval frequency and the operations to be carried out are outlined in the maintenance prog...

Page 11: ...it in non flammable solvent or solvent with a high flash point Leave the element to dry fully Soak the element in clean engine oil and remove the excess oil The engine will smoke when it is started fo...

Page 12: ...humid Clean the exterior of the generating set and apply a rustproofing product Drain fuel from fuel tank carefully Gasoline left in the fuel tank will eventually deteriorate making engine starting d...

Page 13: ...oose spark plug cap Check spark plug for contamination Remove spark plug and clean electrodes If loose push spark plug cap back into place If connected turn off the power switch on the connected appli...

Page 14: ...fixed sales date with a shop stamp factory serial number and originals of sales and ware receipt issued by salesman are subjects of warranty Within the warranty period the service center eliminate fre...

Page 15: ...www fubag ru FUBAG FUBAG 4 1 1...

Page 16: ...www fubag ru 5 1 5 0 5...

Page 17: ...www fubag ru 6 1 30...

Page 18: ...www fubag ru 7 1 2 1 2 3 4 220 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15...

Page 19: ...4 15 C 40 C 60 4 10 C 1 100 WHS 190 DC WHS 210 DC 230 230 50 50 4 5 5 4 4 5 18 2 20 5 cos 25 25 1 1 1 1 89 92 729x537x592 729x537x592 50 190 60 210 65 65 60 A 120 140 4 5 IP23 1 6 SAE 10W30 DC 1 HOND...

Page 20: ...www fubag ru 9 1 10 10 1 2 20 10 0 10 20 30 40 4 14 32 50 68 86 104 5W 10W 20W 20 30 40 10W 30 10W 40 C F...

Page 21: ...www fubag ru 20 5 1 2 3 5 OPEN 4 OPEN CLOSE OPEN 1 2 3 5 4...

Page 22: ...www fubag ru 21 1 2 3 4 1 1 2 3 OFF 4 1000 3 5 300 2 3 2 0 3 0 2 0 50 80 A 3 0 4 0 3 2 70 120 A 4 0 6 0 4 0 110 170 A 7 0 5 0 140 210 A...

Page 23: ...www fubag ru 22 5 5 15 6 50 25 100 300 3...

Page 24: ...www fubag ru 3 2 25 50 1 2 3 4 5 6 1 2 3 0 7 0 8 4 1 2 1 8 1 4 1 2 3 4 0 7 0 8...

Page 25: ...www fubag ru 4 2 1 2 3 7 2 1...

Page 26: ...www fubag ru 5 2 8 CLOSE ON ON...

Page 27: ...www fubag ru 6 2 10 9...

Reviews: