4. Connection and Operating mode

U

(CHARGE)

se in charging mode

These models can charge the battery in automatic mode (electrical control) or manual which
requires supervision by the user. In the automatic mode, you protect the electronic of your car and
you do not need supervision.
- Use an indoor well ventilated premise.
- Remove the battery caps if available and check that the level of liquid is correct; if not, top up with
distilled water. Clean well the battery terminals.
- Switch off the power supply by selecting position “0”. Then, plug in your equipment.
- Select the correct voltage 12 or 24 V by using appropriate commutator.
- Connect the clamps (”+” red, “-” black) to “+” and “–” battery terminals, making sure you get a good
electric contact.
- Switch the commutator to charging mode and then set the charging current to the minimum using
the potentiometer. After that switch the power on, on position “1”.
- After one minute charging current, adjust the charging current by using the potentiometer. A normal
charging current should be in excess 1/10 of the battery capacity.
- On “electronic mode”, when the charging process is over, a light will show on.
- On “manual mode”, stop the charging process when your battery starts to boil. Be careful about
explosive gas, avoid flames or sparks.

Summary of Contents for DRIVE 1200/24T

Page 1: ...nnecting and disconnecting the battery Position the machine in the room so that the panel should be easily accessible Install the unit on a firm level surface Carefully read the instruction manual and...

Page 2: ...0 10 V Connect the device to be performed by specialists who have appropriate qualifications Remove the battery caps if there is and check the level of liquid If it is not correct filled up with disti...

Page 3: ...ement needs to be done manually The protection against the transformer overloads or starting on the charge position is ensured by a circuit breaker on the front panel of the machine If it trips a manu...

Page 4: ...cting position 0 Then plug in your equipment Select the correct voltage 12 or 24 V by using appropriate commutator Connect the clamps red black to and battery terminals making sure you get a good elec...

Page 5: ...re than 5 seconds at a time and wait 2 minutes before to do an other try Otherwise your equipment may go under thermal protection wait 10 minutes Batteries sulfated or damage The DRIVE does not reveal...

Page 6: ...t voltage The ammeter needle does not deviate Because of a too intensive use the thermal protection of your device has been activated Wait for about 5 o 10 minutes in order to allow the device to cool...

Page 7: ...irs When sending the for warranty repair please ensure that the is packed in the original packaging the set is complete perator s anual During warranty period the service centre eliminates manufacturi...

Page 8: ...www fubag ru FUBAG FUBAG 1 III 8...

Page 9: ...2 www fubag ru 9 220 380 10 DRIVE 700 24 DRIVE 1200 24T 220 380 12 24 12 24 70 80 45 60 Min Max 45 675 65 900 400 780 700 1200 30 56 10 40 10 40 40 20 50 90 50 90...

Page 10: ...www fubag ru 10 3 DRIVE 1 4 1 4 2 3 DRIVE 700 24 1200 24T 10A 45A 15A 40A 60A 45 675 Ah 65 900 Ah 45 150 Ah 45 220 Ah DRIVE 700 24 1200 24T 220 1 380 3 16A 16A...

Page 11: ...www fubag ru 11 4 O 12 24 ELECTRONIC CONTROL ON OFF 1 8 10 1 A 12 14 8 24 29 6 12 24 1 55 A 1 110 A 55 110 10 16 5A manual ON 0...

Page 12: ...www fubag ru 12 O I 1 5 5 O Electronic Control 12 14 8 24 29 6 Manual DRIVE a b 5...

Page 13: ...www fubag ru 13 5 CHARGE 2 5 12 24 DRIVE 12 24 5 10 12 24 DRIVE 12 24 20A charge START 12 24 12 DRIVE 6...

Page 14: ...www fubag ru 14 7 8...

Reviews: