Page 9/15 

700-THS3    Rev. 6 -05 May 2015  

Chapter 3

 

Sensor Quick Setup Guide 

This chapter will take you through the steps to set up (configure) the THS3 with an Axiom datalogger.  
It is meant as a quick reference.  Detailed instructions can be found in the Axiom User Guide and 
Axiom Configuration Reference.   
 

NOTE:  

After installation, the sensor should be given a minimum of thirty minutes to 

acclimatize to a site before data is taken. 

3.1

 

Configuring the THS-3 

1)

 

Connect the THS-3 to the data logger on the red Temperature and Humidity port. 
 

2)

 

From the data logger’s home page, select the Sensors icon. 

 

 

Figure 3-1: Home Page 

 

The next screen (SDI Sensor Mapping) will display the icons of the dedicated sensors which 

 

are already added and set up.  

 
3)

 

To add the THS-3, select the Add icon, then press on the Air icon. 

 

       

 

Figure 3-2:  Adding the THS-3 

Summary of Contents for THS-3

Page 1: ...1 800 548 4264 www ftsenvironmental com 700 THS3 Rev 6 05 May 2015 THS 3 Temperature and Humidity Sensor Installation and Quick Setup Guide...

Page 2: ...ental com 700 THS3 Rev 6 05 May 2015 Contact information FTS 1065 Henry Eng Place Victoria B C V9B 6B2 CANADA www ftsenvironmental com Toll free 1 800 548 4264 Local 250 478 5561 Technical support htt...

Page 3: ...1 General Description 3 1 2 Specifications 4 Chapter 2 Installation and Maintenance 5 2 1 General 5 2 2 Tower Mounting 5 2 3 Maintenance 7 Chapter 3 Sensor Quick Setup Guide 9 3 1 Configuring the THS...

Page 4: ...humidity 0 to 1 Vdc equals 0 to 100 RH on the sensor connector The T H sensor assembly see Figure 1 1 houses the sensors and associated electronics Both sensors are protected from air borne contamina...

Page 5: ...und Power Humidity Output K Temperature Ground thermistor others No Connect Table 1 THS Sensor Signal Connections 1 2 Specifications The specifications for the THS 3 Temperature and Humidity Sensor ar...

Page 6: ...eight Correct installation height is dependent on regulations for the jurisdiction in which the equipment is to be deployed Ensure you review local regulations prior to installation In the United Stat...

Page 7: ...2015 Figure 2 1 Attaching the assembly to the support arm 2 Loosely attach the support arm to the mast or tower with the clamp bolts at the desired sensor height Ensure the support arm s V is fitted t...

Page 8: ...n the open in a shade free area to ensure accurate temperature readings b The sensor should be well away from external sources of heat i e any equipment at the site that might generate heat c The sens...

Page 9: ...en key to remove the three bolts securing the base of the sensor to the base plate of the housing assembly Figure 2 4 Sensor base showing bolts c Gently remove the sensor and inspect the filter for cl...

Page 10: ...ce NOTE After installation the sensor should be given a minimum of thirty minutes to acclimatize to a site before data is taken 3 1 Configuring the THS 3 1 Connect the THS 3 to the data logger on the...

Page 11: ...t select the F radial button Humidity This is the relative humidity Clip at 0 100 If checked causes the datalogger to limit humidity values read from the sensor to the range of 0 to 100 That is any ai...

Page 12: ...Line Logging does not have the full functionality as setting up Logging through the Data screen 1 Select the Edit button then Input the desired the Logging Interval press on the hour minute or second...

Page 13: ...bed here are displayed in blue Logging intervals created using the In line Logging feature are displayed in green Figure 3 6 Logging Intervals 3 Press the Add icon then the Edit icon Set the desired l...

Page 14: ...he Home page 3 4 Confirm Sensor Operation Now that the THS 3 is setup confirm its operation and ensure data is being logged 1 From the Home page select the Data icon to display the Data Status screen...

Page 15: ...turn to the Home page 3 5 Changing the Setup If you want to change the setup from the Home page select the blue Sensors icon then select the THS icon Select the Set up Cog which will bring you to the...