700 – Axiom - H1 Overview– Rev 7 - 03 Aug 2017
29/37
Chapter 5
Specifications
__________________________________________________________________________________
5.1
Datalogger
General
5.1.1
5.1.1.1
Protection
Inputs are lightning / static protected
Connectors are metal shell circular waterproof types
Built-in case temperature sensor
5.1.1.2
Physical
Size:
25 cm wide, 20 cm high. 15 cm deep (10” x 8” x 6”)
Weight:
3.3 kgs (7.3 lbs)
4.2 kgs (9.2 lbs) with optional internal G6 G6 Transmitter
5.1.1.3
Environmental
Operating Temperature Range
-40 ºC to 60 ºC (refer to the display specification for the display’s
operating temperature range)
Storage Temperature Range
-50 ºC to 70 ºC
Enclosure
watertight, even without connectors attached
5.1.1.4
Power management
9.6 Vdc to 20 Vdc operating voltage
Internal solar panel voltage and current measurement
Internal battery voltage, current, and temperature measurement
Internal, temperature compensated battery charge regulator
5.1.1.5
Power consumption
State
Current draw
without internal G6
transmitter
with internal G6
transmitter
Idle
3 mA with )
8 mA
Active
10 mA
15 mA
Display On
60 mA
65 mA
Transmit
n/a
2.6 A max