background image

PROPRIETARY INFORMATION

All information in this manual is proprietary to and the 
property of FSR inc. This publication is protected by the Federal 
Copyright Law, with all rights reserved. No part of this document 
may be reproduced, transcribed, or transmitted, in any form or by 
any means, without prior explicit written  permission from FSR 
Inc.

Operators Safety Summary

The general safety information in this summary is for operating 
personnel.

Read Instructions 

Read and understand all safety and operating 

instructions before using this equipment. Keep the instructions 
handy.

Do Not Remove Covers or Panels 

There are no user-serviceable 

parts within the unit. Removal of the top cover will expose 
dangerous voltages. To avoid personal injury, do not remove the 
top cover. Do not operate the unit without the cover installed.

Power Source 

This product is intended to operate from the  

specifi ed wall plug-in transformer.  Do not use any other power 
source.

Grounding the Product

 This product is grounded through the 

grounding conductor of the power cord. To avoid electrical shock, 
plug the power cord  into a properly wired receptacle before 
connecting to the product input or output terminals.
 

Use the Proper Power Cord 

Use only the power cord and 

connector specifi ed for your product. Use only a power cord that is 
in good condition. Refer cord and connector changes to qualifi ed 
service personnel.

Do Not Operate in Explosive Atmospheres 

To avoid explosion, 

do not operate this product in an explosive atmosphere.

TECHNICAL SPECIFICATIONS

RS-232 DATA INPUT

Number/Type: 

1- DB-9 female connector.  DCE type connection for direct 
connection to a PC serial port.

Handshaking:

Local loop back only

RS-232 type

Bidirectional, full duplex

RS-232 DATA OUTPUT

Number/Type: 

 1- DB-9 male connector.  DTE type connection for direct 
connection to peripheral.

Data Rate:

0-115k baud

INFRARED INPUT

Number/Type: 

1- 3.5 mm mini jack center positive

Compatibility

 

Compatible with most IR outputs designed to drive an IR 
emitter LED.

INFRARED OUTPUT

Number/Type:

Dual output on 3 pin pluggable Phoenix connector for 
connection to multiple IR emitters.

Output Switch

2 position dip switch (Normal 12 mW/High 60mW)

Carrier Range

0-200 kHz

POWER

T2-DTXW and T2-DRX:  9 [email protected] or [email protected].  
Power supplies are provided

MECHANICAL

Transmitter enclosure

Metal   1.70”W x0.93”D x4.09”H

Shipping weight 

1 lbs.

Receiver enclosure

Metal  4.22”W x3.93”D x1.59”H

Shipping weight 

1.2 lbs.

GENERAL

UTP cable wiring standard 
/ type

EIA / TIA-568B   CAT5, 5E, 6

Recommended transmission 
range

0-1000 ft 

ACCESORIES

1 rack unit mounting kit to fi t a standard 19” rack FSR part 
number 16214

Summary of Contents for TWISTER 2

Page 1: ...Some states do not allow the exclusion of incidental or consequential damages so the above limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Warranty claims should be accompanied by a copy of the original purchase invoice showing the purchase date if a Warranty Registration Card was mailed in at the time ...

Page 2: ...rd Use only the power cord and connector specified for your product Use only a power cord that is in good condition Refer cord and connector changes to qualified service personnel Do Not Operate in Explosive Atmospheres To avoid explosion do not operate this product in an explosive atmosphere TECHNICAL SPECIFICATIONS RS 232 DATA INPUT Number Type 1 DB 9 female connector DCE type connection for dir...

Page 3: ...Cat 5 5E 6 type cable Cable runs of over 1000 feet are within the capabilities of the product These high quality devices ensure reliable error free data transmission that is immune to interference from electrical noise FEATURES RS 232 Data Transmission DB 9 female connectors for the inputs and male for outputs UTP connections are via RJ 45 Connectors EIA TIA 568B Compatible with RS 232 standards U...

Page 4: ...SERIAL OUT DB 9 male port See pinout IR Control Installation Confirm and observe polarity on all external devices before proceed ing Connect the IR output device to the 3 5mm jack on the face of the T2 DTXW Transmitter Connect the IR emitter s to the pluggable phoenix connector on the T2 DRX Receiver using the wiring diagram provided Emitters are available from FSR Use FSR part number 28397 Once th...