PROPRIETARY INFORMATION
All information in this manual is proprietary to and the
property of FSR inc. This publication is protected by the Federal
Copyright Law, with all rights reserved. No part of this document
may be reproduced, transcribed, or transmitted, in any form or by
any means, without prior explicit written permission from FSR
Inc.
Operators Safety Summary
The general safety information in this summary is for operating
personnel.
Read Instructions
Read and understand all safety and operating
instructions before using this equipment. Keep the instructions
handy.
Do Not Remove Covers or Panels
There are no user-serviceable
parts within the unit. Removal of the top cover will expose
dangerous voltages. To avoid personal injury, do not remove the
top cover. Do not operate the unit without the cover installed.
Power Source
This product is intended to operate from the
specifi ed wall plug-in transformer. Do not use any other power
source.
Grounding the Product
This product is grounded through the
grounding conductor of the power cord. To avoid electrical shock,
plug the power cord into a properly wired receptacle before
connecting to the product input or output terminals.
Use the Proper Power Cord
Use only the power cord and
connector specifi ed for your product. Use only a power cord that is
in good condition. Refer cord and connector changes to qualifi ed
service personnel.
Do Not Operate in Explosive Atmospheres
To avoid explosion,
do not operate this product in an explosive atmosphere.
TECHNICAL SPECIFICATIONS
RS-232 DATA INPUT
Number/Type:
1- DB-9 female connector. DCE type connection for direct
connection to a PC serial port.
Handshaking:
Local loop back only
RS-232 type
Bidirectional, full duplex
RS-232 DATA OUTPUT
Number/Type:
1- DB-9 male connector. DTE type connection for direct
connection to peripheral.
Data Rate:
0-115k baud
INFRARED INPUT
Number/Type:
1- 3.5 mm mini jack center positive
Compatibility
Compatible with most IR outputs designed to drive an IR
emitter LED.
INFRARED OUTPUT
Number/Type:
Dual output on 3 pin pluggable Phoenix connector for
connection to multiple IR emitters.
Output Switch
2 position dip switch (Normal 12 mW/High 60mW)
Carrier Range
0-200 kHz
POWER
T2-DTXW and T2-DRX: 9 [email protected] or [email protected].
Power supplies are provided
MECHANICAL
Transmitter enclosure
Metal 1.70”W x0.93”D x4.09”H
Shipping weight
1 lbs.
Receiver enclosure
Metal 4.22”W x3.93”D x1.59”H
Shipping weight
1.2 lbs.
GENERAL
UTP cable wiring standard
/ type
EIA / TIA-568B CAT5, 5E, 6
Recommended transmission
range
0-1000 ft
ACCESORIES
1 rack unit mounting kit to fi t a standard 19” rack FSR part
number 16214