Installation and Operation
Mount the units as appropriate for the particular installation.
There are tapped holes on the top and bottom of the T2-DRX for mount-
ing. Use screws that protrude through no longer than 1/2".
The T2-DTXW resembles standard duplex outlet shape and will mount
into a standard gang box. Connect the RJ-45 jack and power supply
leads BEFORE mounting the unit in the gang box. Always check for
cable clearance while mounting.
The input power connector is NOT polarity sensitive and should be con-
nected to the provided supply to both the transmitter and receiver. Do
not plug in the supplies until all cables are tested.
UTP Installation
Install and terminate the UTP cable, taking note of the following. The
cable must be terminated using the EIA/TIA-568B standard pairing.
Where possible, the use of pre terminated, pretested cables is highly
recommended. If fi eld termination is required, be sure to use a commer-
cially available cable tester to confi rm the proper wiring.
While Cat 5/5E cables are the most commonly used with the system
other types of UTP cable can be used successfully.
RS-232 Installation
Connect the RS-232 output of the PC or control system to the T2-DTXW
transmitter module "SERIAL IN" DB-9 female port. Connect the periph-
eral to the T2-DRX "SERIAL OUT" DB-9 male port. (See pinout)
IR Control Installation
Confi rm and observe polarity on all external devices before proceed-
ing.
Connect the IR output device to the 3.5mm jack on the face of the T2-
DTXW Transmitter.
Connect the IR emitter(s) to the pluggable phoenix connector on the T2-
DRX Receiver using the wiring diagram provided. Emitters are available
from FSR. Use FSR part number 28397.
Once the interconnect cables are tested, Plug in both power supplies and
perform a fi nal operation check.
TYPICAL APPLICATION
MECHANICAL DIMENSIONS
1.70
4.09
.93
.27
2.72
IR IN
IR IN
POWER
SERIAL IN
T2-DTXW
UTP OUTPU
OUTPUT
TO TWISTER 2
RECEIVER
12VDC/0.1A
9VAC/0.2A
POWER
244 Bergen Blvd.
West Paterson, NJ
07424
1
2
3.93
3.69
4.22
1.59
2
IR
RxD
Serial
Normal
1
T2-DRX
TxD
Power
IR Power
High
Data/IR Receiver
Power
9
V
AC/0.2
A
UT
P
Input
from
T
wister 2
T
ransmitter
Data/IR Receiver
2
IR Out
1
Gnd
Serial Out
12
V
AC/0.1
A
1
2
2
IR
RxD
Serial
Normal
1
T2-DRX
TxD
Power
IR Power
High
Data/IR Receiver
Power
9VAC/0.2A
UTP Input
from Twister 2
Transmitter
Data/IR Receiver
2
IR Out
1
Gnd
Serial Out
12VAC/0.1A
IR IN
POWER
SERIAL IN
T2-DTXW
UTP OUTPUT
TO TWISTER 2
RECEIVER
12VDC/0.1A
9VAC/0.2A
POWER
244 Bergen Blvd.
West Paterson, NJ
07424
RN-1000/RN-8200
OR CONTROL
SYSTEM
RS-232
T2-DTXW
FRONT
T2-DTXW
BACK
RJ-45
TWISTED PAIR
UP TO 1000'
O 1000'
T2-DRX
BACK
T2-DRX
FRONT
RS-232
CONTROLLED
DEVICE
IR EMITTERS
OPTIONAL
FSR #28397 (2x)
IR CONTROLLED
DEVICE
TO AC
POWER
TO AC
POWER
PROJECTOR
PROJECTOR