NOTES: 

1.25VHP  

Wiring Rev 1A  

Date 04-06-11 

 

Identified Terminal 

 

Emergency cool switch UP 

Center position OFF 

Emergency Heat switch Down 

 

Controller no jumper 

Compressor and Reversing 

valve energized for heat 

Fan speed 

Relay 24 volt  

Fan indoor 

supply

 

Low 

RED 

 

Fan Capacitor 

 

2

5

7

Transformer 

24 volt AC 

Compressor 

relay 24 volt 

RVR 24 volt

115 volt 

30 A  

Field 

receptacle 

Fuse 2 Amp 

2

5

7

Run 

Capacitor 

Start 

Capacitor

P

T

C

R

YEL 

YEL 

RED 

WHT 

RED 

BLK 

BLK 

RVS 

HPS 

WHT 

BLK 

RED 

BLKD

PUR 

BLK 

RED 

WHT 

High 

BLK 

Rear of 

Interface 

connector to 

controller 

WHT 

RED 

ORG 

BLK 

BLK 

RESISTANCE 

HEAT

LIMIT 

SWITCH

2

5

7

24v S 

Therm 

Therm 

24v R 

NU 

Fan 

Comp 

Rev V 

Yel 

BLK 

BLK 

YEL 

YEL 

WHT 

BLK 

Emergency heat 

and cool switch 

PUR 

BLU 

BLK 

HPC 

LPC 

C

THR 

RV

Y  

Out 

R

B

C

Y

D

OCT 

OAT 

FAN 
FAN 

THR 

CC 

RED 

Yel 

RED 

RED 

2

5

7

BLK 

PUR 

BLK 

PUR 

Resistance 

heat relay 

24 volt

C

O

M

L

O

W

H

I

G

H

Fan 

Capacitor

FAN 

MOTOR

BRN

WHT

BRN 

Defrost timer board 

2

5

7

HPS relay

ORG

RED 

R

S

Comp & 

Overload 

C

Select switch

res heat or 

heatpump

PUR 

Summary of Contents for F-DI1.25VHP ECU

Page 1: ...FSI 1 25 Ton AC Heat Pump Unit Operational Guide for F DI1 25VHP ...

Page 2: ...ressures moving parts and high electrical voltages and current that can do bodily injury or can kill an untrained person all warning labels should be read and complied with Basic setup Position the ECU in the required location to allow for the supplied ducting to be connected to the shelter and the installation of the power supply and control cabling There should be adequate clearance on all sides...

Page 3: ...nected to the ECU with watertight turn lock connectors When connecting the controller cable to both the ECU and Controller you may hear a click when it locks in place The temperature sensing is done at the intake duct of the ECU so the controller can be placed inside or outside depending on your final needs Powering up the ECU The power supply should be a 100 to 125 volt single phase supply Do not...

Page 4: ...troller cable connection on the ECU to select resistance heat only Cold weather R heat only this will transfer the Heatpump power to the second resistance heater The first resistance heater is controlled by the ECU s operation and is transparent to the user Turn on the power supply circuit breaker The ECU s fan will immediately start to circulate the air within the shelter but no heating or coolin...

Page 5: ...he asterisk is displayed the controller is actively operating the ECU compressor and or optional electric resistance heat Any adjustments to temperature setting can be done while the controller is operating Simply change the temperature setting by pressing the Higher or Lower arrow buttons Once the desired temperature is shown on the controller it will be accepted as the new setting The controller...

Page 6: ...n a warm humid condition it may require a significant amount of time for the ECU to reach the desired temperature The ECU will dehumidify the space first and then lower the temperature second The ECU during it s heating mode at certain outside temperatures will develop frost and ice on the outside coils In order to maintain the optimum conditions for heating the ECU will automatically go into a de...

Page 7: ...gency operation mode The ECU can be manually operated in the case of a controller failure loss if the control cable gets damaged or an internal relay becomes inoperable The emergency bypass should only be used when there is an issue that cannot be resolved and heating or cooling is mandatory Care should be taken not to switch between heating and cooling or on and off without allowing at least a 3 ...

Page 8: ...mpressor was running it will stop The ECU fan will continue to circulate air until it is turned of at the power supply breaker This is normal operation Turn off the power supply breaker Remove the plug from the power source Remove the ducting and controller cable from the ECU Clean and store the ducting controller and ECU unit Storage of the ECU is best in a clean dry location ...

Page 9: ...r Start Capacitor P T C R YEL YEL RED WHT RED BLK BLK RVS HPS WHT BLK RED BLKD PUR BLK RED WHT High BLK Rear of Interface connector to controller WHT RED ORG BLK BLK RESISTANCE HEAT LIMIT SWITCH 2 5 7 24v S Therm Therm 24v R NU Fan Comp Rev V Yel BLK BLK YEL YEL WHT BLK Emergency heat and cool switch PUR BLU BLK HPC LPC C THR RV Y Out R B C Y D OCT OAT FAN FAN THR CC RED Yel RED RED 2 5 7 BLK PUR ...

Page 10: ... S Black F Therm Green H Therm White G 24v R Red B NU E Fan Yellow D Comp Orange C Rev V Blue Controller cable receptacle and controller interface connector Controller Controller cable Wiring details Viewed from the rear of the plugs A 24v S Black F Therm Green H Therm White G 24v R Red B NU E Fan Yellow D Comp Orange C Rev V Blue Wiring details viewed from the rear of the receptacle ...

Page 11: ... airflow to the condenser section is blocked or obstructed by dirt the unit can shut down due to over pressure disconnect the supply cord and allow the unit to cool for several minutes clean or unblock the condenser and retry the ECU This is normal during cooler weather the ECU will switch to resistance heat as the condenser thaws it will switch back to heat pump mode When the condenser freezes th...

Reviews: