© 2015 Flanders Scientific, Inc.
41
Color Management Menu
Drag and drop the custom LUT files to the monitor. It will take a few moments to
transfer.
You may load up to three custom LUTs at a time. (“user1”, “user2”, and “user3”)
Once the file has finished transferring, on the monitor go to:
Menu \ Color Management \ Update LUT
Press ENTER to begin the process, and confirm with Yes when the monitor prompts
you.
The update process will take approximately 6 minutes per LUT on monitors with first
generation CFE boards and about 15 seconds per LUT on units with CFE2 boards.
Upon completion of the LUT transfer, power cycle the monitor.
Custom LUTs can be accessed from the Color Management menu by selecting Color
Space: USER1, USER2, USER3. Press ENTER to confirm your selection.
Monitors with a first generation CFE board (LM-2461W, LM-2460W, CM-170W) utilize the .dat LUT format for calibration
LUTs.
Monitors with a second generation CFE board (CFE2) running firmware version 9.53-1935 or later utilize a .cfe LUT format
for calibration LUTs and a .dat LUT format for DIT LUTs. Units with CFE2 boards include:
-CM171
-CM172
-CM240
-CM250
-CM320TD
-CM420TD
-CM500TD
-BM090
-BM210
-BM230