Data Center, Enterprise & ISP Network Solutions
12
Hard disk in place, and normal activities
The flash frequency of the hard disk itself OFF
Hard disk failure
N/A
ON
Hard disk is positioned
N/A
4HZ blinks
Hard disk is in Rebuild state
N/A
1HZ blinks
3.8 PCIe Slot Distribution Rear Overview
The slot provided by I/O module 1 is Slot 9 ~ Slot 10; the slot provided by I/O module 2 is Slot 4 ~ Slot 8;
the slot provided by I/O module 3 is Slot 1 ~ Slot 3.
2.5'' HDD or SSD can be connected on the I/O module 1
The I/O module 2 can be connected to the hard disk module and the PCIe expansion module. The Slot 7 to
Slot 8 can only connect to the 2*PCIeX8 or 1*PCIeX16. When the 3.5” hard disk module is connected, the
Slot 4 to the Slot 6 cannot receive any other extensions. Module; When connected to a 2.5” hard disk
module, Slot 4 to Slot 5 are occupied and can only expand 1* PCIeX8; when Slot 4 to Slot 6 use two PCIe
riser modules, Slot 5 is unavailable.
The I/O module 3 can be connected to a hard disk module and a PCIe expansion module. When a 3.5"
hard disk module is connected, Slot 1 to Slot 3 cannot be connected to any other expansion module; when
a 2.5" hard disk module is connected, Slot 1 to Slot 2 is occupied, can only expand 1* PCIeX8; When Slot 1
~ Slot 3 adopts PCIe riser module of 2 slots, Slot 2 is not available.
The server supports variable fan speeds. In general, the fan rotates at the lowest speed. If the server
temperature increases, the fan will increase the speed to cool down.
Four Fans