5-2
5.2
Operator Troubleshooting Guides
Problem
Probable Causes
Corrective Action
BURNERS DO NOT
LIGHT
(Main gas supply
valve verified to be
open, the gas valve is
verified to be ON, and
power switch is
verified to be ON.)
A.
Ignition module lockout (the
burners failed to light within 4
minutes).
Indicator
: Amber trouble light
on control panel is illuminated.
A.
Turn the switch to the OFF po-
sition. Wait 60 seconds and
turn the power to the ON posi-
tion. Wait at least 4 minutes.
B.
Stuck water level float switch.
(If the float switch does not indi-
cate sufficient water in the cook-
pot, it will not allow the burners
to fire.)
B.
Remove the probe block cover
and clean the float switch with
a solution of detergent and
water.
NOTE:
Do not use
deliming solution.
C.
Failed power switch.
C.
Call FAS.
D.
Failed ignition module or gas
valve, or broken or loose wiring.
C.
Call FAS.
COOKPOT DID
NOT FILL WHEN
VALVE WAS
TURNED ON
(Water supply to unit
verified to be ON.)
A.
Failed water valve.
A.
Call FAS.