Frymaster LOV BIGL30 Series Installation, Operation And Maintenance Manual Download Page 11

1-4 

 
When ordering parts, the following information is required: 

 

Model Number: 

 

Serial Number: 

 

Type of Gas or Voltage: 

 

Item Part Number: 

 

Quantity Needed: 

 

 

Service information may be obtained by contacting your local FAS/Distributor.  Service may also be obtained by 
calling the Frymaster

 

Service Department at 1-800-551-8633 or 1-318-865-1711 or by email at 

[email protected]

.  When requesting service, please have the following information ready: 

 

Model Number: 

 

Serial Number: 

 

Type of Gas: 

 

 

In addition to the model number, serial number, and type of gas, please be prepared to describe the nature of the 
problem and have ready any other information that you think may be helpful in solving your problem. 
 

RETAIN AND STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE USE.

 

Summary of Contents for LOV BIGL30 Series

Page 1: ...CTIONS Page 2 1 OPERATING INSTRUCTIONS Page 3 1 OPERATING THE BUILT IN FILTRATION SYSTEM Page 4 1 PREVENTIVE MAINTENANCE Page 5 1 OPERATOR TROUBLESHOOTING Page 6 1 Part Number FRY_IOM_8196966 01 2019...

Page 2: ...n excess of psi 3 5 kPa 13 84 inches W C The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply p...

Page 3: ...er used in a mobile or marine installation or concession Warranty protection is only offered for fryers installed in accordance with the procedures described in this manual Mobile marine or concession...

Page 4: ...ce is not intended for use by children under the age of 16 or persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision c...

Page 5: ...he oil which may cause severe burns WARNING Do not overfill the frypot to avoid overflow of hot oil that may cause severe burns slipping and falling WARNING Use caution and wear appropriate safety equ...

Page 6: ...ment Components that are not part of the frypot assembly such as the blower gas valve micro switches doors and cabinetry are not covered by the frypot warranty Leaks due to abuse or from threaded fitt...

Page 7: ...mage in shipment abnormal use removal alteration or obliteration of either the rating plate or the date code on the heating elements operating the frypot without shortening or other liquid in the fryp...

Page 8: ...f infrared burner assemblies mounted on each side of the frypot A dedicated blower mounted on the front of the frypot supplies combustion air for the burners Manual LOV Gas fryers can be configured fo...

Page 9: ...rmful interference in which case the user will be required to correct the interference at his own expense The user is cautioned that any changes or modifications not expressly approved by the party re...

Page 10: ...acked before leaving the factory The transportation company assumes full responsibility for safe delivery upon its acceptance of the equipment for transport What to do if your equipment arrives damage...

Page 11: ...ter Service Department at 1 800 551 8633 or 1 318 865 1711 or by email at service frymaster com When requesting service please have the following information ready Model Number Serial Number Type of G...

Page 12: ...ion in this manual and local or nation al codes or regulations installation and operation shall comply with the codes or regulations in force in the country in which the equipment is installed DANGER...

Page 13: ...e lower edge of the grease filter Frymaster recommends that the minimum distance be 24 in 600 mm from the flue outlet to the bottom edge of the filter when the appliance consumes more than 120 000 BTU...

Page 14: ...power outage Do not attempt to operate this appliance during a power outage 2 1 4 Australian Requirements To be installed in accordance with AS 5601 local authority gas electricity and any other relev...

Page 15: ...fryer electrical cord s into a grounded electrical receptacle b Place the computer switch in the ON position Verify that the display indicates MLT CYCL c Place the computer power switch in the OFF po...

Page 16: ...ER All connections must be sealed with a joint compound suitable for the gas being used and all connections must be tested with a solution of soapy water before light ing any pilots Never use matches...

Page 17: ...1 28 30 37 II2Esi3P G20 G25 20 25 G31 50 GERMANY DE II2ELL3B P G20 G25 20 G30 G31 50 I3P G31 50 HUNGARY HU II2HS3B P G25 25 G30 G31 50 CYPRUS CY CZECH REPUBLIC CZ GREECE GR IRELAND IE ITALY IT PORTUGA...

Page 18: ...of the frypot Light the fryer described in the Lighting Instructions topics found in Chapter 3 of this manual DANGER Dry firing your unit will cause damage to the frypot and can cause a fire Always e...

Page 19: ...o withstand the higher caloric value of the Propane gas Burners designed for use in propane units may be used in natural gas applications but not vice versa Non CE Gas Conversion Kits Natural Gas to P...

Page 20: ...f the frypot to verify that the unit is level both side to side and front to back To level fryers adjust the casters being careful to ensure the fryer s are at the proper height in the frying station...

Page 21: ...Secure Strap or Restraint to floor with appropriate fastener NOTE Bent link on Chain Retstraint goes to floor REAR OF FRYER 2 Close fryer drain valve s 3 Clean and fill frypot s to the bottom oil leve...

Page 22: ...LOV SERIES GAS FRYER CHAPTER 3 OPERATING INSTRUCTIONS TYPICAL CONFIGURATION BIGL330 SHOWN NOTE The appearance of your fryer may differ slightly from that shown depending upon the configuration and da...

Page 23: ...filtration draining and cleaning procedures CAUTION The cooking oil capacity of the MANUAL LOV Series gas fryer is 32 lbs 3 8 gallons 14 5 liters at 70 F 21 C for a full vat Before lighting the fryer...

Page 24: ...ontroller for normal cooking temperature 3 If the burners fail to light press the ON OFF switch to the OFF position and wait 60 seconds Repeat step 2 4 The fryer will automatically enter the melt cycl...

Page 25: ...ake opening until a bright orange red glow is obtained Carefully hold the plate in position and tighten the locking nut 3 3 Shutting the Fryer Down For short term shut down during the workday place th...

Page 26: ...In Filtration System for Use with Filter Paper or Filter Pad The FootPrint Pro filtration system allows the oil in one frypot to be safely and efficiently filtered while the other frypots in a battery...

Page 27: ...positioning it under the drain Figure 2 Figure 3 Figure 4 4 2 Filtration An M3000 controller prompts the user when to filter on the Manual LOV fryer if option is selected in setup After a preset numbe...

Page 28: ...tial for severe burns DANGER DO NOT hammer on the drain valve with the cleanout rod or other objects Damage to the ball inside will result in leaks and will void the Frymaster warranty 4 After the oil...

Page 29: ...ils on the fryer s joiner strip The strip is present to seal the joint between the fry vessels Banging fry baskets on the strip to dislodge shortening will distort the strip adversely affecting its fi...

Page 30: ...AL container must be able to withstand the heat of the oil and hold hot liquids 3 Follow the instructions for disposing of oil on page 1 13 in the controller manual Open the drain valve slowly to avoi...

Page 31: ...metal surfaces and compo nents to remove accumulations of oil and dust Clean the outside of the fryer cabinet with a clean damp cloth soaked with McDonald s All Purpose Concentrate removing oil dust a...

Page 32: ...on of hot water and McDonald s All Purpose Concentrate Rinse and thoroughly dry each part DO NOT use steel wool or abrasive pads to clean these parts The scratches that result from such scrubbing make...

Page 33: ...Shortening Disposal Unit MSDU a built in filtration unit or a portable filter unit These units are not intended for this purpose and will be damaged by the solution DANGER Remove all drops of water fr...

Page 34: ...s the switch twice to display the set point The setpoint is the temperature with a dot after it 4 Note the temperature on the thermometer or pyrometer All three readings should be within 5 F 2 C of ea...

Page 35: ...and wires with plastic wrap or a plastic bag Figure 3 4 Remove the plastic wrap from the blower motor assembly Reassemble the blower motor assembly and blower housing Reinstall the blower assembly in...

Page 36: ...osition of the plate to open or close the air intake opening until a bright orange red glow is obtained Carefully hold the plate in position and tighten the locking nut s TYPICAL BLOWER ASSEMBLY SOME...

Page 37: ...ners and associated components i e gas valves pilot assemblies ignitors etc are in good condition and functioning properly Inspect all gas connections for leaks and verify that all connections are pro...

Page 38: ...return handle one at a time in the ON position Ve rify that the pump activates and that bubbles appear in the oil of the associated frypot Close all oil return valves i e place all oil return handles...

Page 39: ...at failure of a small component may often be indicative of potential failure or incorrect functioning of a more important component or system If you are in doubt as to the proper action to take do not...

Page 40: ...s valve knob to the ON position C Verify that any in line manual shut off and gas main valve is open D Verify that the quick disconnect fitting on the flexible gas line is firmly connected to the frye...

Page 41: ...F Turn the controller on to check temperature If the desired scale is not displayed repeat Controller displays High limit failure disconnect power A Open drain valve B Failed high limit A Close the dr...

Page 42: ...at oil is in drain pan Press CONFIRM and follow directions for FILL VAT FROM DRAIN PAN 6 2 4 Error Log Codes For M3000 Controller Only Code ERROR MESSAGE EXPLANATION E03 ERROR TEMP PROBE FAILURE Temp...

Page 43: ...of the waste tank Connect pins 2 and 3 to the fresh oil pump Set the fryer to bulk through the vat setup mode on the far left controller See M3000 Manual LOV controller manual section 2 9 on page 2 10...

Page 44: ...ocker panel A 1 3 Fill Vat from Bulk Tank 1 Ensure vat is empty and the drain valve is closed 2 At the rocker panel switch to Bulk Mode 3 Open the return valve on the empty tank Press the Add Fresh Oi...

Page 45: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 46: ..._IOM_8196966 01 2019 8197423 WWW WELBILT COM Welbilt provides the world s top chefs and premier chain operators or growing independents with industry leading equipment and solutions Our cutting edge d...