![Frymaster FilterQuick FQG30 Service Manual Download Page 45](http://html1.mh-extra.com/html/frymaster/filterquick-fqg30/filterquick-fqg30_service-manual_2340461045.webp)
1-40
Problem
Probable Causes
Corrective Action
Actuator doesn’t
function cont.
C.
AIF board failure.
D.
Actuator readings are out of tolerance.
E.
Actuator defective.
C.
Check power on the connector of the
problem actuator while trying to
manually open or close an actuator.
Pins 1 (Black) and 4 (White) should
read +24VDC when the actuator is
opening. Pins 2 (Red) and 4 (White)
should measure -24VDC when the
actuator is closing). If either voltage is
missing, the AIF board is likely bad.
Test the actuator by plugging into
another connector. If the actuator
operates, replace the board.
D.
Check resistance of the potentiometer
between pin 3 (blue wire) and pin 4
(gray/white wire). Closed should read
0-560
Ω
. Open should read 3.8K
Ω
–
6.6K
Ω
.
E.
If proper voltages are present at the
connector and actuator doesn’t operate
reset power to the fryer, if it still
doesn’t operate replace the actuator.
Actuator functions on
wrong vat.
A.
Actuator plugged into wrong connector.
B.
Locator pin is in wrong position.
A.
Ensure the actuator is plugged into
correct connection (J1 for FV return,
J3 for DV return and J6 for FV drain
and J7 for DV drain).
B.
Ensure the locator pin is in proper
position in plug J2. See table B on
page 1-65.
Summary of Contents for FilterQuick FQG30
Page 8: ...1 3 ...
Page 41: ...1 36 1 16 2 Bulk Wiring ...
Page 56: ...1 51 1 18 6 Clogged Drain Failed Oil Sensor Error Flowchart ...
Page 57: ...1 52 1 18 7 Menu Trees 1 18 7 1 FilterQuick Controller Setup Menu Tree ...
Page 58: ...1 53 1 18 7 2 FilterQuick Filter and Info Mode Menu Tree ...
Page 62: ...1 57 1 20 Principal Wiring Connections ...
Page 63: ...1 58 1 21 Wiring Diagrams 1 21 1 Main FQG 230 430 120V CE Export ...
Page 64: ...1 59 1 21 2 Main FQG 230 430 Australia ...
Page 65: ...1 60 1 21 3 Main FQG 230 430 120V CE Export with Solid Shortening ...
Page 66: ...1 61 1 21 4 Main FQG 230 430 Australia with Solid Shortening ...
Page 67: ...1 62 1 21 5 Main FQG 330 530 120V CE Export ...
Page 68: ...1 63 1 21 6 Main FQG 330 530 Australia ...
Page 69: ...1 64 1 21 7 Main FQG 330 530 120V CE Export with Solid Shortening ...
Page 70: ...1 65 1 21 8 Main FQG 330 530 Australia with Solid Shortening ...
Page 71: ...1 66 1 21 9 Transformer Filter Box 430 530 ...
Page 73: ...1 68 1 22 2 FilterQuick FQG30 Series Simplified Wiring with Push Buttons ...
Page 74: ...1 69 1 22 3 FilterQuick FQG30 Series Data Network Flowchart ...
Page 76: ...1 71 1 24 Shortening Melting Unit Wiring Diagram ...
Page 77: ...1 72 1 25 Modular Basket Lift Wiring Diagram 100 120V ...
Page 78: ...1 73 1 26 Modular Basket Lift Wiring Diagram 208 250V ...