2-9
Switching to a different type of gas without installing the proper conversion components
may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY
FOR WHICH IT IS NOT CONFIGURED!
Conversion of this appliance from one type of gas to another should only be performed
by qualified, licensed, and authorized installation or service personnel, as defined in
Section 1.7 of this manual.
FilterQuick™ FQG30 series gas fryers manufactured for non-CE countries use different burners for each
type gas. The burners in fryers built for Propane gas have a special gray-colored coating on the burner
tiles to enable them to withstand the higher caloric value of the Propane gas. Burners designed for use in
propane units may be used in natural gas applications, but not vice versa.
Non-CE Gas Conversion Kits
Natural Gas to Propane (LP) Gas
Propane (LP) Gas to Natural Gas
Full Vat PN 826-2965
Full Vat PN 826-2967
Dual Vat PN 826-2966
Dual Vat PN 826-2968
Non-CE Gas Conversion Kits for Australia
Natural Gas to Propane (LP) Gas
Propane (LP) Gas to Natural Gas
Full Vat PN 826-2969
Full Vat PN 826-2971
Dual Vat PN 826-2970
Dual Vat PN 826-2972
Units manufactured for export to CE countries are equipped with “universal” burners that may be used
with either Natural (G20, G25) gas or Butane (G30) and Propane (G31) gasses.
CE Gas Conversion Kits for Units with Gas Valve 810-1715
G20 or G25 (Natural) to G30 or G31 Gas:
G30 or G31 to G20 or G25 (Natural) Gas:
PN 826-2975
PN 826-2976
CE GAS CONVERSION INSTRUCTIONS
1. Between G20- and G25-type Natural Gas, adjust the gas pressure at the regulator. (Refer to the CE
Standard Burner Manifold Gas Pressure Chart.) Do not change the orifice.
2. Between a 2
nd
family (G20 or G25) and a 3
rd
family gas (G30 Butane or G31 Propane):
a. Change the orifices.
b. Adjust the manifold pressure.
3. Remove the old rating plate and return to Frymaster. Affix the new rating plate included with the
conversion kit in place of the old rating plate stating the gas has been converted.