FGP55 SERIES GAS RETHERMALIZERS
CHAPTER 1: SERVICE PROCEDURES
1-14
1.6.7 Replacing the Cookpot (cont.)
10.
Remove screws securing flue-cap
braces to cookpot (a nut-driver
with an extension or long
screwdriver is required). Use care
not to drop the screws into the
flues. If this happens, the screws
can be retrieved when the flue is
removed (Step 12). Use a
screwdriver or similar tool to free
flue cap from cookpots. Remove
flue cap by lifting up and off of
rethermalizer.
11.
Remove gas manifold pipe for
access to gas manifold shield by
disconnecting at the unions.
Ensure gas supply is shut off and
supply line is disconnected prior
to removing. Set gas manifold
aside. Remove screws securing
gas manifold shield. Remove
shield to access water-return
plumbing components connected
to the cookpots.
Removing flue cap.
Removing gas manifold shield.