NOTICE 

All units shipped without factory supplied cords and plug assemblies must be 
hardwired using flexible conduit to the terminal block located on the rear of the unit.  
These units should be wired to NEC specifications.  Hardwired units must include 
installation of restraint devices. 
 

 

 DANGER 

Adequate means must be provided to limit the movement of this appliance without 
depending on or transmitting stress to the electrical conduit.  A restraint kit is provided 
with the fryer.  If the restraint kit is missing contact your local Frymaster Factory 
Authorized Service Center (FASC) for part number 810-3574. 

 
 

NOTICE 

If this equipment is wired directly into the electrical power supply, a means for 
disconnection from the supply having a contact separation of at least 3-mm in all poles 
must be incorporated in the fixed wiring. 

 

NOTICE 

This equipment must be positioned so that the plug is accessible unless other means 
for disconnection from the power supply (e.g., a circuit breaker) is provided. 

 

NOTICE 

If the electrical power supply cord is damaged, it must be replaced by a Frymaster Dean 
Factory Authorized Service Center technician or a similarly qualified person in order to 
avoid a hazard. 

 

NOTICE 

If this appliance is permanently connected to fixed wiring, it must be connected by 

means of copper wires having a temperature rating of not less than 167°F (75°C).  

 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for FE155

Page 1: ...pment Service Association recommends using CFESA Certified Technicians 24 Hour Service Hotline 1 800 551 8633 SEPT 2008 PRINTED IN THE USA www frymaster com Email service frymaster com 8196399 FE155 R...

Page 2: ...PART AND OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER DANGER Improper installation adjustment maintenance or service and unauthorized alterations or modifications can cause property damage inj...

Page 3: ...Class A or B limits for radio noise emissions as set out by the ICES 003 standard of the Canadian Department of Communications Cet appareil numerique n emet pas de bruits radioelectriques depassany le...

Page 4: ...SC for part number 810 3574 NOTICE If this equipment is wired directly into the electrical power supply a means for disconnection from the supply having a contact separation of at least 3 mm in all po...

Page 5: ...eral Installation Requirements 2 1 Caster Leg Installation 2 2 Pre Connection Preparations 2 2 Connection to Electrical Supply 2 3 Power Requirements 2 4 Wiring Diagrams 2 5 CHAPTER 3 Operating Instru...

Page 6: ...Distributor Information may also be obtained by calling the Frymaster Technical Service Department at 1 800 551 8633 or 1 318 865 1711 When requesting service please have the following information re...

Page 7: ...with a shadowed box like the one at right 1 5 Installation Operating and Service Personnel Operating information for Frymaster equipment has been prepared for use by qualified and or au thorized pers...

Page 8: ...aim Procedure Your Frymaster equipment was carefully inspected and packed before leaving the factory The transportation company assumes full responsibility for safe delivery upon acceptance of the equ...

Page 9: ...ble CE codes All units cord connected or permanently connected should be connected to a grounded power supply system A wiring diagram is located on the inside of the unit door Refer to the rating plat...

Page 10: ...instructions see illustration below If the re straints are disconnected for service or other reasons they must be reconnected before the fryer is used DANGER Adequate means must be provided to limit t...

Page 11: ...left off entirely whichever you prefer If the unit is to be moved frequently for cleaning or preventive maintenance Frymaster recommends installing flexible water lines If the cooker is hard plumbed t...

Page 12: ...neutral and ground and be oil and water resistant Power Requirements Use copper wire ONLY suitable for at least 170 F 75 C ELECTRIC COOKER MODEL FE155 Volts Phase kW Amps per leg Minimum Wire Size 20...

Page 13: ...2 5 Field Connection Wiring Diagrams...

Page 14: ...Vat Low Level Float Switch Upper Level Float Switch Controller Lid Element Drain Inlet Overflow Bezel Cabinet Interior Main Power Switch Drain handle Drain extension NOTE The water inlet is controlle...

Page 15: ...when the cook time elapses Cook cycles won t start if the computer is displaying LO Remove the product and press the timer key to halt the alarm Boil Press the boil key Display changes to boil Wait u...

Page 16: ...ds WARING Raise the lid slowly Trapped steam may escape from beneath the lid CAUTION The electronic circuitry in your computer can be affected adversely by current fluctuations and electrical storms S...

Page 17: ...the cookpot with a solution of cold water and 1 cup of detergent 2 Place the unit into operation in accordance with Section 3 4 3 Press the 30 minute timer key Allow the unit to go through two simmer...

Page 18: ...hes with a solution of detergent and warm water A Scotchbrite or equivalent nylon pad may be used to scrub away any accumulated mineral deposits Verify that both floats move freely up and down on the...

Page 19: ...erature and high limit probes are properly connected tightened and func tioning properly and that mounting hardware and probe guard are present and properly installed Verify that component box and con...

Page 20: ...n Keep in mind that failure of a small component may often be indicative of potential failure or incorrect functioning of a more important component or system If the troubleshooting and corrective act...

Page 21: ...sembly see Section 4 1 Autofill does not shut off when the cookpot is full B Malfunctioning solenoid valve B Call ASA Water will not heat computer is on water is at normal level but LO is not showing...

Page 22: ...er L L C 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 688 2200 FAX Tech Support 1 318 219 7135 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1 800 551 8633 819 6399 SE...

Reviews: