![Frymaster 8196203 Installation, Operation, Service, And Parts Manual Download Page 14](http://html1.mh-extra.com/html/frymaster/8196203/8196203_installation-operation-service-and-parts-manual_2340391014.webp)
3–2
Shutdown
1.
Turn the fryer off.
2. Filter the cooking oil and clean the fryers (See Chapters 4 and 5).
3. Place the frypot covers on the frypots.
3.2
Operation of the Solid-State Analog Controller
NOTE:
Refer to Chapter 4 of this manual for operating instructions for the built-in filtration system.
Fryers configured for the U.S. Navy are equipped with solid-state analog controllers.
1
3
4
5
6
2
7
U.S. Navy Solid-State Analog Controller
ITEM
DESCRIPTION
1
Power Switch – Controls electrical power to fryer.
2
Power-On Light – Indicates when electrical power to fryer is ON.
3
Heating Mode Light – Indicates when heating element is ON.
4
Trouble Light – Indicates over high-limit or problem in heat control circuitry.
5
Thermostat Control Knob – Sets desired frying temperature.
6
Hi-Limit Test Switch – Tests high-limit thermostat.
7
Second Hi-Limit Test Light – Indicates fryer is in second high-limit test mode.
The analog controller, illustrated above, is used to adjust and maintain oil at the temperature
indicated by the thermostat knob.
The fryer has two built-in high-limit protection features. If the temperature in the frypot reaches
approximately 410°F, the controller opens the heat relay circuit, turning the elements off. If the
temperature in the frypot reaches 450
°
F, a mechanical high-limit shuts off electrical power to the
elements.
The operator should periodically test each of the high-limit protection features, using
the procedure at the end of this chapter, to verify that they are operating correctly.
Summary of Contents for 8196203
Page 48: ...7 18 7 14 Wiring Diagram Wiring Harness...
Page 59: ...8 10 8 3 2 Drain Valve Assembly and Assoc Parts cont Units with Built In Filtration...
Page 70: ...8 21 8 5 Filtration System Components 8 5 1 FPH17 Filtration Components...
Page 74: ...8 25 8 6 Frypot Assembly and Thermostat Frypot P N 823 5359SP Thermostat P N 806 7543...
Page 75: ...8 26 8 7 Oil Return System Components...