Frymaster 819-5432 Maintenance  Requirement Card Download Page 13

2 of 9 
© 2000 McDonald’s Corporation 

 

819-5432 NOV 05 

All Rights Reserved 

 

      

        Card 15

 

Recovery Check Time 

(With MACC100 computer only.) 

8.

 

Start the recovery check by touching the following: 

a.

 

Full-vat: Right 

 

button. 

b.

 

Split-vat: Left 

 

button for the left or right 

 

button for the right side. 

Note: The display will show "REC xxx F" (or xxx C) indicating the actual vat 
temperature. 

9.

 

When the display shows a vat temperature of 270°F (132°C) and is automatically 
stabilized at that temperature, agitate the cooking oil for one minute. 

10.

 

The computer automatically starts the time check when the vat temperature exceeds 
274°F (134°C).  Do not agitate further. 

11.

 

At the end of the check, the display will show the recovery time as "xxx SEC".  The 
computer again controls the fryer for a vat temperature equal to the set temperature. 

12.

 

The recover test information may be recalled at any time by touching the respective 

 

button. 

Note: Recovery time should be less than 145 seconds for a gas fryer and less than 100 
seconds for an electric fryer. 

13.

 

If the required recovery time cannot be attained, call service representative. 

14.

 

To exit the recovery time check, press the 

 twice, first turning the computer OFF, 

then turning the computer back ON. 

15.

 

Repeat Steps 1 through 15 for each additional fryer until all have been checked.  
Recovery time check is complete. 

 

Recovery Check Time 

(With Thermostat Controller only.) 

1.

 

Grease filters should be in place and properly cleaned. 

2.

 

Turn vat controller “ON” and let cooking oil stabilize at cooking temperature. 

3.

 

Allow the fryer to cycle OFF after reaching the cooking temperature. 

4.

 

The cooking oil should be at the normal (upper) oil-level line at cooking temperature.  
Add or remove cooking oil as needed.

  

All cooking oil should be melted before 

proceeding. 

5.

 

Insert the fry vat probe at the rear of the frypot, to within one (1) inch of the tip of the 
computer probe.  If using the Pro Fry computer, display temperature PC# 326/327 or 
NCC #1540/1541, the computer probe should be used. 

6.

 

Turn the thermostat knob to 270°F (132°C) and allow vat to cool for approximately 30 
minutes. 

7.

 

When the display reads 270°F (132°C), turn the thermostat knob to 375°F  (191°C) and 
begin timing. 

8.

 

Record the time it takes for the cooking oil to reach 320°F (160°C). 

Note: Recovery time should be less than 145 seconds for a gas fryer and less than 100 
seconds for an electric fryer. 

 

Continued from previous 
page. 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
When 

Monthly 
 

Tools 

Stopwatch, digital 
thermometer with fry vat 
probe or Pro Fry computer, 
probe holder, paper, pen.

 

15

 

Summary of Contents for 819-5432

Page 1: ...gles to protect against any loose debris 5 Check the inside of the hood to ensure it is clean and free of grease 6 Inspect the inside of the stack with a flashlight Ensure that is clean and free of gr...

Page 2: ...the cooking computer to ON and set it to the product to be cooked in the vat 2 Allow the vat to cycle OFF after reaching the cooking temperature 3 The cooking oil should be at the normal upper oil lev...

Page 3: ...computer display temperature PC 326 327 or NCC 1540 1541 the computer probe should be used 5 Allow the vat to cycle ON and OFF three times 6 After the stabilizing period the instant vat cycles ON for...

Page 4: ...buildup This also meets McDonald s cleanliness standards Not cleaning behind the fryers on a weekly basis could become a fire hazard to your restaurant 1 Turn all fryer power switches to OFF 2 Remove...

Page 5: ...tioner a nylon pot brush and the high low brush scrub all the areas listed in order in Step 12 including the floor 14 Wipe all areas with towels until clean and dry 15 Have manager inspect and approve...

Page 6: ...ut and allow the cooking oil to drain from fry vat Flush out any pieces of fried food and sediment 5 Close the drain valve and very carefully pour McD Heavy duty Degreaser HCS 2 full gallons 8 liters...

Page 7: ...k proportioner If a sink proportioner is not being used mix 6 fluid ounces 3 4 cups 177 ml of McD A P C HCS to 3 gallons 11 liters of warm water and pour solution into fryer vat 19 Using a nylon pot b...

Page 8: ...it vat section into fryer pot without splattering 6 Remove fryer capping piece assembly if so equipped to expose carbon build up 7 Finish filling the vat to the normal shortening level line with a hot...

Page 9: ...here is any carbon left in the vat clean it now with nylon scouring pad then rinse and drain vat 20 Rinse fryer vat thoroughly TWO TIMES with warm 100 F 38 C water and wipe with damp towel Close the f...

Page 10: ...the sink proportioner the use of HOT water will reduce warm up time 8 Press the to turn fryer ON Computer will display low temp 9 Press the gray product button used to store boil out programming 10 T...

Page 11: ...pan or the cooking oil disposal cart Caution Do not splash solution on skin or clothing Bucket and solution will be hot 22 Remove bucket and discard solution into sink drain 23 Place bucket under frye...

Page 12: ...ow the fryer to cycle OFF after reaching the cooking temperature 4 The cooking oil should be at the normal upper oil level line at cooking temperature Add or remove cooking oil as needed Note All cook...

Page 13: ...st turning the computer OFF then turning the computer back ON 15 Repeat Steps 1 through 15 for each additional fryer until all have been checked Recovery time check is complete Recovery Check Time Wit...

Page 14: ...yers recovery time is acceptable If the time displayed is greater than the required time refer to the scratch calibration procedure on this card or the Fryer section of the Equipment Manual for Troubl...

Page 15: ...s absolutely necessary but with extreme care The computer must be replaced immediately after this period of necessity If the second high limit does not work the vat must NOT be used until the second h...

Page 16: ...oil after completing this check Note Only one side of a split vat is to be checked at a time Caution Grease filters must be in place and exhaust fans must be ON during entire high limit control check...

Page 17: ...due to be changed Discard the cooking oil after completing this check Note The cooking oil must be at a high enough level to cover the high limit probe Note Grease filters must be in place and exhaus...

Page 18: ...limit thermostat immediately 5 High limit control check is complete 6 Repeat the same procedure for other vats Caution If after completing both high limit tests you find only the second high limit op...

Page 19: ...ture until the mechanical high limit opens approximately 425 F 218 C The right display will then show Hi 2 10 Failure of high limit test 2 is indicated by an alternating display of hi 2 and bad Call f...

Page 20: ...d through the burner viewing ports or if there are dark spots on the burner face After 90 seconds of continuous burner operation the burner should glow bright orange red For proper colors see the BURN...