If after having carried out this procedure you have not been able to precisely adjust the front 

glasses, please contact the technical support team of Frost-trol, S.A. 

 

Summary of Contents for ONEGA R290

Page 1: ...TRANSLATION OF THE ORIGINAL DOCUMENT For additional copies visit www frost trol com Versi n 7 D004002 Difusi n Restringida Interna INSTALLATION AND MAINTENANCE MANUAL ONEGA R290 SOLID LINES...

Page 2: ...DAMAGE SUSTAINED IN TRANSIT 11 1 9 TECHNICAL ASSISTANCE 11 1 10 STORAGE 11 2 INTALLATION OF REFRIGERATED DISPLAY CABINET 12 2 1 CABINET LOCATION 12 2 2 UPACKING 12 2 3 LEVELLING 13 2 4 THERMOSTATIC V...

Page 3: ...t www frost trol com ONEGA R290 SOLID LINES Versi n 7 2 Difusi n Restringida Interna 6 1 MALFUNCTIONS 27 6 1 1 THE UNIT DOESN T START UP OR IT STOPS 27 6 1 2 THE UNIT DOES NOT GET COLD ENOUGH 27 6 2 F...

Page 4: ......

Page 5: ...ause the unit to break down It s mandatory to leave 8cm between the cabinet rear wall and the supermarket wall to ensure the airflow Keep clear of obstructions all ventilation openings of the cabinet...

Page 6: ...on internal servicing of the unit The power cords must be properly spread out safe from shocks and far from liquids water and heat sources and in perfect condition The use of adaptor plugs is forbidd...

Page 7: ...ating layers on the external walls of the equipment as this could compromise cabinet performance In order to reduce flammability related risks this cabinet may only be installed by suitably qualified...

Page 8: ...s been especially designed with a view to assist maintenance staff by facilitating the installation of these cabinets thus making their task more pleasant as well as to gain optimal productivity from...

Page 9: ...e cabinet has a wide range of optional accessories If you need details about its assemblage please contact with Frost trol S A 1 2 GENERAL CHARACTERISTICS PVTR7813C 780 30 3 4 135 5 1 4 230 9 1 8 876...

Page 10: ...TDA values and the maximum and minimum product temperature In order to access the EPREL database you can either scan the QR code from the energy label provided with the appliance or access the EPREL...

Page 11: ...class for refrigeration cabinets TEMPERATURE CLASS TEMPERATURE OF APPLICATION MAXIMUM TEMPERATURE OF THE HOTTEST PRODUCT MINIMUM TEMPERATURE OF THE COLDEST PRODUCT C C C L1 15 18 15 18 L2 12 18 12 18...

Page 12: ...Should you have any technical queries concerning the installation of the refrigerated display cabinet or cooling system please contact our Technical Department If you need to get in contact with Fros...

Page 13: ...rom their condensing units into the cabinet or onto its condensing unit The refrigerated display cabinet must not be installed in places where explosive gases are present Do not expose the equipment t...

Page 14: ...to remain horizontal This will ensure that the bases on the end sections do not need to be excessively extended 2 4 THERMOSTATIC VALVE CONTROL In order to obtain maximum evaporator efficiency the expa...

Page 15: ...serve all of your country s safety regulations in full Before plugging into the mains check that the supply voltage is the same as the voltage indicated on the nameplate The electricity supply should...

Page 16: ...erna Earthing is mandatory according to current legislation as is providing protection against power surges short circuits and indirect contacts 2 6 CLEANING Before the first use it s mandatory to cle...

Page 17: ...WN DEF Table 4 Display The temperature controls and defrost times that we recommend for each cabinet are based on our experience and laboratory tests Different air conditions could require controls th...

Page 18: ...ters FREQUENT Set the desired value 5 Press SET The display will show the parameter name This is the current value of the parameter 6 Press UP CC or DOWN DEF The value on the display will increase or...

Page 19: ...rms with manual reset can be reset by pressing the PRG and UP CC for more than 3 s 3 6 MANUAL DEFROST As well as the automatic defrost function a manual defrost can be enabled if the temperature condi...

Page 20: ...products to ensure perfect air circulation around them Gloves should be worn when loading products into the cabinet The cabinet doors should be closed as long as possible In this way excessive energy...

Page 21: ...LEANING CONDENSER MONTHLY MAINTENANCE DOORS MONTHLY CLEANING GENERAL EVERY 2 OR 3 MONTHS Table 9 Cleaning routine Do not allow any water to spatter or be sprayed over the unit s electrical elements Sh...

Page 22: ...the process It may scratch or damage inner surfaces Clean inner parts with warm water and neutral soap Dry the surface with a soft cloth Ensures all the surface are well dried Close the cabinet doors...

Page 23: ...um cleaner Mount and screw the front grille Finally plug de cabinet The condenser s coil must be cleaned 12 times a year Otherwise the efficiency of the appliance might drop significantly 4 4 FRONT GL...

Page 24: ...he levelling of the appliance shall be checked both longitudinally and transversally 2 If the appliance is not levelled in some of its directions remove the bottom coverings for enabling access to the...

Page 25: ...INSTALLATION AND MAINTENANCE MANUAL TRANSLATION OF THE ORIGINAL DOCUMENT For additional copies visit www frost trol com ONEGA R290 SOLID LINES Versi n 7 24 Difusi n Restringida Interna...

Page 26: ...or additional copies visit www frost trol com ONEGA R290 SOLID LINES Versi n 7 25 Difusi n Restringida Interna If after having carried out this procedure you have not been able to precisely adjust the...

Page 27: ...s indicated inside the refrigerated cabinet on the characteristics plate Taking the customer s standing position as a reference You may request to Frost trol the spare parts cross section Table 10 Nam...

Page 28: ...d limit and the conservation temperature is suitable for the products Check that there is no air flow that will affect the operation of the unit Check that condenser is free of dust or any other mater...

Page 29: ...r etc a handmade drawing or photos could be appreciated Thermostat setting Defrost interval Defrost endurance time End defrost temperatura State of the fans on defrost cycle on off Evaporating pressur...

Page 30: ...he collection centre specified by the local authorities for recovery and recycling of professional WEEE In the case of trade in of the old product for a new one the user can ask the seller to take del...

Page 31: ...terials used for its production any content of lead mercury hexavalent chrome polybrominated biphenyl PBB and polybrominated diphenil ether PBDE does not exceed in weight 0 1 that of cadmium does not...

Page 32: ...trol S A Technical Department Avda del Castell Vell 176 12004 Castell n Spain Phone 0034 964 34 27 40 Fax 0034 964 21 51 48 e mail frost trol frost trol com www frost trol com Difusi n Restringida In...