INSTALLATION AND MAINTENANCE MANUAL
TRANSLATION OF THE
ORIGINAL DOCUMENT
For additional copies visit:
www.frost‐trol.com
ONEGA R290
SOLID LINES
Versión: 7
-10-
Difusión Restringida Interna
temperatures and humidity conditions that are higher than those for which they
have been designed.
1.5.
FIXATION OF THE RECOMMENDED TEMPERATURE
IN EACH COMPARTIMENT
Each cabinet, depending on the model and its options, is technically defined by a
different temperature depending on the application and it’s designed for preserving
a certain type of product.
TEMPERATURE
CLASS
TEMPERATURE OF
APPLICATION
MAXIMUM
TEMPERATURE
OF THE
HOTTEST
PRODUCT
MINIMUM
TEMPERATURE
OF THE
COLDEST
PRODUCT
[ºC]
[ºC]
[ºC]
M0 0/1 +4
-1
M1 0/+2 +5 -1
M2 +2/+4 +7 -1
H2 +4/+8
+10 -1
Table 2. Temperature depending on class for refrigeration cabinets.
TEMPERATURE
CLASS
TEMPERATURE OF
APPLICATION
MAXIMUM
TEMPERATURE
OF THE
HOTTEST
PRODUCT
MINIMUM
TEMPERATURE
OF THE
COLDEST
PRODUCT
[ºC]
[ºC]
[ºC]
L1 -15/-18
-15 -18
L2 -12/-18
-12 -18
L3 -12/-15
-12 -15
Table 3. Temperature depending on class for freezing cabinets.
1.6.
OPERATING THE COOLING SYSTEM
The condensing unit requires an air temperature of at least 20ºC and a maximum
of 30ºC for efficient ventilation of the condenser. The minimum temperature of the
condenser should never fall below 20ºC.
1.7.
RECEIPT OF REFRIGERATED CABINET
Check the unit carefully to make sure that it is not damaged and no part or
accessory is missing. For information about missing parts or accessories please
contact the Frost-Trol Commercial Department or our official representative for
your country.
This refrigerated display cabinet has been thoroughly inspected to ensure the
highest level of quality. Any order for components should be made to Frost-Trol or
Summary of Contents for ONEGA R290
Page 4: ......