IMPORTANT!
The surfaces that the lines are to be placed on may not be perfectly horizontal.
Therefore it would be best to first take the section of line that is to be placed onto
the highest part of the surface and screw its adjustable bases to their smallest
possible heights whilst allowing the section to remain horizontal. This will ensure
that the bases on the end sections do not need to be excessively extended.
2.4.
ELECTRICAL CONNECTION
The assembly, installation and connection of these cabinets must be
carried out by a certified technician.
Consult the circuit diagrams that are supplied with each cabinet when carrying out
the electrical connections and observe all of your country’s safety regulations in
full.
Before plugging into the mains, check that the supply voltage is the same as the
voltage indicated on the nameplate. The electricity supply should be adequate for
maximum consumption.
The power cords must be properly spread out, safe from shocks and
far from liquids, water and heat sources, and in perfect condition. The
use of adaptor plugs is forbidden.
If the power cord is damaged, it must be replaced by the
manufacturer in order to avoid a hazard.
Technical cabinet data are showed in the nameplate (see Chapter 5).
Electric diagrams are in the electric box inside a plastic package.
Earthing is mandatory according to current legislation, as is providing
protection against power surges, short circuits and indirect contacts.
This cabinet is provided with quartz infrared halogen lamps. For its installation and/
or handling, follow the recommendations described in Chapter 4.
2.5.
EQUIPOTENTIAL BONDING
It is mandatory to plug the appliance to the user’s equipotential system by the
connection point identified by the symbol IEC60417-5021.