FROST ITALY s.r.l.

 -Via Trasimeno 46-int.1 – Z.I. – 36015 Schio – Vicenza – Italy 

Tel. +39/+445/576772 – Fax +39/+445/576775 – e-mail [email protected]

 

3

 

GARANZIA

 

WARRANTY

 

climatizzatori 

della 

FROST 

ITALY 

godono  di  una  GARANZIA  SPECIFICA, 
secondo  normativa  europea,  che  decorre 
dalla  data  di  acquisto  dell’apparecchio  e  
che  l’utente  è  tenuto  a  documentare;  nel 
caso non sia in grado di farlo, la garanzia 
decorrerà  dalla  data  di  fabbricazione 
dell’apparecchio.

 

The units produced by FROST ITALY have a 
SPECIFIC  WARRANTY  (in  accordance  with 
the european regulation) starting from the 
selling    date  that  has  to  be  proved  by  the 
user. In the case the user cannot show any 
documentation  the  warranty  will  start 
from the manufacturing date.

 

 
 

IN ALCUNE PARTI DEL MANUALE 

SONO UTILIZZATI SIMBOLI DAL 

SEGUENTE SIGNIFICATO: 

IN THIS MANUAL WILL BE USED 

SOME SYMBOLS LIKE  

THE FOLLOWING:

 

 

ATTENZIONE

 = per azioni che richiedono particolare cautela ed adeguata 

preparazione 

ATTENTION

= for actions that can be done only by qualified persons

 

VIETATO

 = per azioni che 

NON DEVONO

 essere assolutamente eseguite 

FORBIDDEN =

 for actions that HAVE ABSOLUTELY NEVER TO BE DONE. 

 
 

ATTENZIONE 

OBBLIGO MONTAGGIO SIFONE SULLO 

SCARICO ACQUA DI CONDENSA 

IN CASO DI ASSENZA LA 

FROST ITALY DECLINA OGNI 

RESPONSABILITA’ SU EVENTUALI DANNI 

 

     ATTENTION

 

THE SIPHON INSTALLATION ON 

DISCHARGE CONDENSATE WATER IS 

COMPULSORY. 

OTHERWISE THE FROST ITALY DOESN’T 

ASSUME ANY LIABILITY FOR POSSIBLE 

CONSEQUENTLY DAMAGES 

 

ATTENZIONE 

VERIFICARE CHE LA CORRENTE ASSORBITA 

DAI VENTILATORI SIA INFERIORE AL 

VALORE DI TARGA RIPORTATO NEI DATI 

TECNICI. 

 

ATTENTION

 

VERIFY THE ADSORBED CURRENT OF 

FANS, IS LESS THAN THE NOMINAL 

CURRENT READ IN THE TECHNICAL 

DATA. 

 
 
 
 
 
 
 

Summary of Contents for ULYSSE 1000

Page 1: ...y Tel 39 445 576772 Fax 39 445 576775 e mail info frostitaly it 1 Recuperatori di calore Heat recovery units ULYSSE MANUALE DI INSTALLAZIONE E MANUTENZIONE INSTALLATION AND MAINTENENCE MANUAL LEGGI E...

Page 2: ...0 600 1000 1500 2000 2500 3000 3600 Are complying at Machine Directive 98 37 CEE Directive PED 97 23 CE Module D1 Electromagnetic Compatibility Directive 89 336 CEE CONFORMITA DICHIARAZIONE DI CONFORM...

Page 3: ...ALE SONO UTILIZZATI SIMBOLI DAL SEGUENTE SIGNIFICATO IN THIS MANUAL WILL BE USED SOME SYMBOLS LIKE THE FOLLOWING ATTENZIONE per azioni che richiedono particolare cautela ed adeguata preparazione ATTEN...

Page 4: ...bale d avviamento La documentazione fornita con l unit deve essere consegnata al proprietario affinch la conservi con cura per eventuali manutenzioni o assistenze GENERAL INSTRUCTIONS Before proceed t...

Page 5: ...tected room from the bad weather with temperatures included between the 20 C and the 55 C MOVIMENTAZIONE DELL UNITA HANDLING OF THE UNIT Le unit FROST ITALY possono essere movimentate sia con carrelli...

Page 6: ...eguito Raising with crane To use a balance or a forked bars Suitably sturdy rope or straps avoid the use of chains Protections to install among strap and machine to avoid that the structure ruins itse...

Page 7: ...n the unit and the other equipment or adjacent structures must be observed In this way the air will be free to circulate and will allow a correct operation from side of the unit and it will be possibl...

Page 8: ...36015 Schio Vicenza Italy Tel 39 445 576772 Fax 39 445 576775 e mail info frostitaly it 8 SCHEMA INSTALLAZIONE A SOFFITTO ROOF INSTALLATION SCHEME 1 0 N 4 SCREW LOCKNUT ISOLATOR SCHEMA INSTALLAZIONE A...

Page 9: ...re negli appositi fori ricavati nei piedini d appoggio dei supporti antivibranti seguendo lo schema indicato di seguito Rubber anti vibrating dampers At the end to avoid the transmission of vibrations...

Page 10: ...HP DIMENTIONAL DRAWING ULYSSE HP RIPRESA ARIA INTERNA A1 SUCTION INDOOR AIR ESPULSIONE ARIA INTERNA A2 INDOOR AIR EXPULSION INGRESSO ARIA RINNOVO B1 INLET RENEWAL AIR MANDATA ARIA RINNOVO B2 DELIVERY...

Page 11: ...prevenire l entrata di odori ed insetti The drainage system should features and adequately sized siphon to ensure free condensate drainage prevent the inadvertent entry of air into the circuit under...

Page 12: ...ione portare il cavo di alimentazione al quadro elettrico all interno dell unit Collegarsi all interruttore rispettando la fasi L il neutro N la terra PE nel caso di alimentazione monofase con neutro...

Page 13: ...connessioni dei conduttori d alimentazione ed il loro stato Verificare il collegamento a terra Verificare il collegamento remoto se installato o la presenza dei ponti sui morsetti ATTENTION Before st...

Page 14: ...lamping state of the connection clamps of the electric power cables and of signal Supervised by the authorized assistance centre To verify that the values of voltage re enter in the described values t...

Page 15: ...0 95 0 82 0 82 Corrente assorbita 1 Input current A 2 9 4 5 4 4 Potenza frigorifera recuperata 1 Recovery cooling capacity kW 0 5 0 7 1 2 1 8 Efficienza recuperatore 1 Recovery efficiency 46 7 44 8 4...

Page 16: ...ecuperata 2 Recovery heating capacity kW 8 0 9 7 11 7 14 0 Efficienza recuperatore 2 Recovery efficiency 47 7 46 3 46 6 46 6 Temperatura di uscita dell aria 2 Outlet air temperature C 6 9 6 6 6 6 6 7...

Page 17: ...se contact the energy supplying agency Check the clamping state of the connection clamps of the electrical board in particular the connection clamps for the compressor automatic switch and control swi...

Page 18: ...FROST ITALY s r l Via Trasimeno 46 int 1 Z I 36015 Schio Vicenza Italy Tel 39 445 576772 Fax 39 445 576775 e mail info frostitaly it 18...

Reviews: