Manual Revision Code: FRONTLINE-SRL-04 10-19-20
10
A. Heat Damage from Weld Spatter or Slag
C. Broken Wires within Strands.
B. Bird Caged
D. Curled, Bent or Kinked
Incorrect Use of SRL
A. Damage due to heat – inside fiber exposed
C. Inside fiber exposed due to cut
B. Separation of layers – stitching was broken
D. Frayed top fibers exposing core of webbing
Inspection requirements for self-retracting devices
ANSI Z359.14-2014
CSA Z2592.2-17
Type of
use
Application
examples
Example conditions of
use
Worker
inspection
frequency
Competent
person
inspection
frequency
Product
revalidation
frequency
Infrequent
to Light
Rescue and
confined
space, factory
maintenance
Good storage
conditions, indoor or
infrequent outdoor
use, room
temperature, clean
environments.
Before each use
Annually
At least every 5
years but not more
than intervals
required by the
manufacturer.
Moderate
to Heavy
Transportation,
residential
construction,
utilities,
warehouse
Fair storage
conditions, indoor and
extended outdoor use,
all temperatures, clean
or dusty
environments.
Before each use
Semi-
annually to
annually
At least every 2
years but not more
than intervals
required by the
manufacturer.
Severe to
continuous
Commercial
construction,
oil and gas,
mining,
foundry
Harsh storage
conditions, prolonged
or continuous outdoor
use, all temperatures,
dirty environment.
Before each use
Quarterly
to semi-
annually
At least annually
but not more than
intervals required
by the
manufacturer.
Notes:
(1) Failure of a worker to perform [before each use] inspection or failure of an inspection by a worker shall
D.
C.
B.
A.
Drawing 3.