45
EN
-U
S
With intermediate lowering, the welding current is lowered to the set lowering current I-2
during the main current phase.
-
To activate intermediate lowering, push the torch trigger forward and hold it in this po
-
sition
-
Release the torch trigger to resume the main current
Spot Welding
If a value has been set for the setup parameter SPt, then 2-step mode operating mode is
the same as spot welding operating mode. The spot welding special display illuminates on
the control panel.
-
Welding: Briefly pull back the torch trigger
The duration of welding corresponds to the value that was entered for the setup pa
-
rameter SPt.
-
Premature ending of the welding process: Pull back the torch trigger again
When using a foot remote control, the spot welding time begins when the foot remote con
-
trol is pressed. Foot remote controls cannot be used to adjust the power.
I
t
I
1
GPr
t
up
t
down
SPt
GPo
I
S
t
E
I
E
t
S
Summary of Contents for TransTig 170
Page 2: ...2...
Page 6: ...6...
Page 18: ...18...
Page 19: ...General Information...
Page 20: ......
Page 24: ...24...
Page 25: ...Operating controls and connections...
Page 26: ......
Page 33: ...Installation and Startup...
Page 34: ......
Page 41: ...Welding Mode...
Page 42: ......
Page 62: ...62...
Page 63: ...Setup Settings...
Page 64: ......
Page 79: ...Troubleshooting and Maintenance...
Page 80: ......
Page 88: ...88...
Page 89: ...Appendix...
Page 90: ......
Page 92: ...92 Safety symbol S Max shielding gas pressure 5 bar 73 psi Noise emissions LWA 68 0 dB A...
Page 98: ......
Page 99: ......