![Fronius TransTig 170 Operating Instructions Manual Download Page 71](http://html1.mh-extra.com/html/fronius/transtig-170/transtig-170_operating-instructions-manual_2339441071.webp)
71
EN
-U
S
In the event of an error:
-
Inspect torch hosepack, welding torch, and grounding cable for damage
-
Check connections and contacts
-
Check the cleanliness of the workpiece surface
Slope Time 1
(only available in 4-step mode)
Ramping time from the main current I
1
to the lowering current I
2
off / 0.01 - 9.9 s
Factory setting: 0.5 s
Slope Time 2
(only available in 4-step mode)
Ramping time from the lowering current I
2
back up to the main current I
1
off / 0.01 - 9.9 s
Factory setting: 0.5 s
Trigger
Torch trigger operating mode
off / on
Factory setting: on
off
Operating welding torch without torch trigger
High frequency ignition is deactivated.
on
TIG 2-step or 4-step mode
HF ignition
off / on
Factory setting: on
off
No HF ignition at the start of welding - welding started by contact ignition
on
HF ignition is activated
The HF ignition special indicator illuminates on the control panel when the "HF
ignition" parameter is set to "on".
Summary of Contents for TransTig 170
Page 2: ...2...
Page 6: ...6...
Page 18: ...18...
Page 19: ...General Information...
Page 20: ......
Page 24: ...24...
Page 25: ...Operating controls and connections...
Page 26: ......
Page 33: ...Installation and Startup...
Page 34: ......
Page 41: ...Welding Mode...
Page 42: ......
Page 62: ...62...
Page 63: ...Setup Settings...
Page 64: ......
Page 79: ...Troubleshooting and Maintenance...
Page 80: ......
Page 88: ...88...
Page 89: ...Appendix...
Page 90: ......
Page 92: ...92 Safety symbol S Max shielding gas pressure 5 bar 73 psi Noise emissions LWA 68 0 dB A...
Page 98: ......
Page 99: ......