58
Measuring points
(continued)
Measuring points
Plug/pin
Measuring result command value
Intermediate circuit voltage 1 TP1-TP3
320 V DC
Intermediate circuit voltage 2 TP5-TP7
320 V DC
Diode check module M1
TP1-TP2 (+)
0.46 V
TP1-TP4 (+)
0.46 V
TP3 (+) - TP2
0.46 V
TP3 (+) - TP4
0.46 V
TP5 - TP6 (+)
0.46 V
TP5 - TP8 (+)
0.46 V
TP7 (+) - TP6
0.46 V
TP7 (+) - TP8
0.46 V
Important!
No continuity during diode check of module M1 with reverse polarity.
NOTE!
The resulting measurement command values change according to the temperature.