64
Supply voltage from intermediate circuit
2 x 230 - 380 V DC
Output voltage
Idle
59 (+/- 2) V
at a load of 4 A
55 (+/- 2) V
Technical Data
Function over-
view
-
Output voltage is electrically isolated and protected by 2 parallel switched PTC
resistors.
-
The 1 V/A falling output characteristic of the NT 60 circuit enables several NT 60
adapters to be connected in parallel.
-
If there is a short circuit, the NT 60 restricts to max. 15 A, using the internal current
limit, until the PTC resistors have reached the switch-off temperature. In the case of
a short circuit, the 55 V supply LED does not flash. As soon as the PTC resistors
trip, the „Error“ LED flashes.
Plug layout
(X1)
(X2)
Fig. 33 Plug on NT 60 mains adapter
Pin 9
Intermediate circuit 1+
Pin 10
NC
Pin 11
Intermediate circuit 1 -
Pin 12
NC
Pin 13
Intermediate circuit 2+
Pin 14
NC
Pin
Function
X1
Connection to wire-feed unit (secondary voltage)
Pin 1
+ 55 V
Pin 2
+ 55 V
Pin 3
GND
Pin 4
GND
X2
Primary connection intermediate circuit 1 and 2
Pin 1
Intermediate circuit 1+
Pin 2
NC
Pin 3
Intermediate circuit 1 -
Pin 4
NC
Pin 5
Intermediate circuit 2+
Pin 6
NC