20
Starting Up for
the First Time
To start Fronius Datamanager 2.0 for the first time,
-
the Fronius Datamanager 2.0 plug-in card must be installed in the inverter,
or
-
there must be a Fronius Datamanager Box 2.0 in the Fronius Solar Net ring.
IMPORTANT!
To establish a connection to Fronius Datamanager 2.0, the end device in
question (e.g., laptop, tablet) must be configured as follows:
-
"Obtain an IP address automatically (DHCP)" must be activated
Connect the inverters with Fronius Datamanager 2.0 or Fronius Datamanager Box 2.0
in Fronius Solar Net
When networking several inverters in Solar Net:
Set the Fronius Solar Net master/slave switch on the Fronius Datamanager 2.0 plug-
in card correctly
-
One inverter with Fronius Datamanager 2.0 = master
-
All other inverters with Fronius Datamanager 2.0 = slave (the LEDs on the Fro-
nius Datamanager 2.0 plug-in cards are off)
Switch the inverters to service mode
-
Activate the WIFI Access Point via the setup menu of the inverter
The inverter establishes the WLAN Access Point. The WLAN Access Point stays open for
one hour.
NOTE!
The Fronius Solar.web App makes starting Fronius Datamanager 2.0 for
the first time significantly easier.
The Fronius Solar.web App is available in the relevant app store.
NOTE!
If the photovoltaic system only has one inverter, the following work steps
1 and 2 can be skipped. Start the process with work step 3 in this case.
1
2
3
Stand by
WiFi Access Point
DATCOM
USB
Clock