Safety Inspections
Safety inspection
This section outlines the safety inspection for the device described in these Service
Instructions.
Please be aware of the requirements and standards relevant to your country, as the
measured values or steps taken during the tests may vary.
Even if there are no relevant requirements and standards in your country, Fronius recom-
mends that this inspection should still be carried out.
The safety inspection must only be carried out on a fully assembled device.
Responsibility
The repair technician is responsible for carrying out and documenting the safety inspec-
tion properly and for making the correct decision regarding the outcome of the inspec-
tion. Fronius will not accept any liability in this regard.
Should any defects be identified during the test, then the entire safety inspection must be
repeated once such defects have been rectified.
The following tests must be performed in the prescribed sequence. Each test must be
passed before the next test is started. If it is not possible to perform a particular test, the
examiner must decide whether the safety of the device can nevertheless still be verified.
The examiner bears full responsibility and liability for this decision. Justifications for the
resulting decision must be documented in the test record under "Comments".
Test record
-
The electrician who performed the tests is responsible for properly recording the test
values in the test record.
-
Document all completed tests in a test record. Enter both the measured values and
the equipment/calibration data used.
-
If an individual test cannot be performed, the resulting decision must be justified and
documented by the examiner.
-
Any device that fails a test must be clearly marked as unsafe and the operator
informed. The device may no longer be used.
The "Safety inspection" test record is available from the DownloadCenter on the Fronius
Partnerweb.
57
EN
Summary of Contents for MTG 2100 S
Page 2: ......
Page 5: ...General information 5 ...
Page 6: ...6 ...
Page 9: ...Error location aid 9 ...
Page 10: ...10 ...
Page 22: ...22 ...
Page 23: ...Replacing modules 23 ...
Page 24: ...24 ...
Page 48: ...48 ...
Page 49: ...Software 49 ...
Page 50: ...50 ...
Page 54: ...54 ...
Page 55: ...Safety Inspections 55 ...
Page 56: ...56 ...
Page 63: ...63 EN ...