Select the relevant menu items:
-
FdA
-
FEd
FdA menu item
-
If Aut is selected, automatic calibration can be carried out in the "FEd" menu item
-
If OFF is selected, manual calibration can be carried out in the "FEd" menu item
FEd menu item
Automatic calibration:
1
Open the clamping lever
2
Press the "Wire threading" button
-
The display will show "run" while the calibration is in progress (duration approx.
25s)
-
Once the calibration has been completed, the digital display will read "FEd"
Manual calibration:
3
Open the clamping lever
4
Press the "Wire threading" button or the torch trigger
-
Display shows „1.St 3.0“ an
5
Press the "Wire threading" button or the torch trigger
-
Display shows "AdJ".
6
Measure the speed at the drive roller and set to 3 m/min (42,3 U/min) using the right
adjusting dial
-
Display shows "rdY". The values have been stored internally
7
Press the "Wire threading" button or the torch trigger
-
Display shows "2.nd 15.0“
8
Press the "Wire threading" button or the torch trigger
-
Display shows "AdJ".
9
Measure the speed at the drive roller and set to 15 m/min (211,7 U/min) using the
right adjusting dial
-
Display shows "rdY". The values have been stored internally
10
Press the "Wire threading" button or the torch trigger
-
Once the calibration has been completed, the digital display will read "FEd"
39
EN
Summary of Contents for MTG 2100 S
Page 2: ......
Page 5: ...General information 5 ...
Page 6: ...6 ...
Page 9: ...Error location aid 9 ...
Page 10: ...10 ...
Page 22: ...22 ...
Page 23: ...Replacing modules 23 ...
Page 24: ...24 ...
Page 48: ...48 ...
Page 49: ...Software 49 ...
Page 50: ...50 ...
Page 54: ...54 ...
Page 55: ...Safety Inspections 55 ...
Page 56: ...56 ...
Page 63: ...63 EN ...