(6)
(6)
(6)
(6)
6
Fit four 2.5x12 TX 10 screws (6) and
close the FSC
Tightening torque= 0.8 Nm
MTG2100S
inspection follow-
ing repairs
Test equipment: insulation measuring
device (e.g. Metriso 5000)
Test voltage: 500 V DC
Measuring points:
-
Between the outer pipe of the torch
body and contact tip; insulation resist-
ance min. 1 M
W
Test equipment: Torch flow rate testbox
(4,078,016)
Perform the tests as described in the
"Torch Flow Rate" Operating Instructions
For the limit values, refer to the "PP-
SER-2001 Welding torch flow rates" ser-
vice test schedule.