64
Special 4-step
mode:
variant 3
Variant 3 of special 4-step mode is activated when the special 4-step mode (SFS) set-up
parameter
-
is set to "3".
In variant 3, push forward and hold the torch trigger to start intermediate lowering. Release
the torch trigger to resume the main current I
1
.
When the torch trigger is pulled back, welding ends immediately without downslope and
final current.
Special 4-step mode: Variant 3
Special 4-step
mode:
variant 4
Variant 4 of the special 4-step mode is activated when the SFS set-up parameter is set to
"4".
-
Welding start-up and welding: briefly pull back and release the torch trigger - the weld
-
ing current will rise at the specified upslope value from the starting current I
S
until it
reaches the main current value I
1
.
-
Push forward and hold the torch trigger for intermediate lowering
-
Release the torch trigger to resume the main current I
1
-
End of welding: briefly pull back and release the torch trigger
Special 4-step mode: variant 4
I
t
I
1
GPr
I
S
G-L / G-H
I
1
I
2
t
up
I
t
I
1
GPr
I
S
t
down
I
E
G-L
G-H
I
1
I
2
t
up
t
E
t
S
Summary of Contents for MagicWave 1700 Job
Page 2: ...2...
Page 18: ...18...
Page 19: ...General information...
Page 20: ......
Page 25: ...Control elements and connections...
Page 26: ......
Page 46: ...46...
Page 47: ...Installation and commissioning...
Page 48: ......
Page 57: ...Welding...
Page 58: ......
Page 86: ...86...
Page 87: ...Setup settings...
Page 88: ......
Page 121: ...Troubleshooting and maintenance...
Page 122: ......
Page 131: ...Appendix...
Page 132: ......
Page 146: ...146...
Page 147: ...147 EN...