St1 | E 5
Cause:
At maximum wire feed speed, the wire-feed motor does not deliver any actual
rotational speed value.
Remedy:
Repeat the push-pull calibration. If the error message re-appears: Contact Af
-
ter-Sales Service.
St1 | E 6
Cause:
At maximum wire feed speed, the wire-feed motor does not deliver any actual
rotational speed value.
Remedy:
Repeat the push-pull calibration. If the error message re-appears: Contact Af
-
ter-Sales Service.
Service codes
shown when the
drive units are en
-
gaged (engaged
calibration)
St1 | E 16
Cause:
Push-pull calibration was interrupted: Quick-stop was activated by pressing
the torch trigger.
Remedy:
Repeat push-pull calibration
St2 | E 7
Cause:
"Push-pull calibration - open-circuit" has not been carried out
Remedy:
Carry out "push-pull calibration - open-circuit"
St2 | E 8
Cause:
At minimum wire feed speed, the wire-feed unit motor does not deliver any ac
-
tual rotational speed value.
Remedy:
Repeat the push-pull calibration. If the error message re-appears: Contact Af
-
ter-Sales Service.
St2 | E 9
Cause:
At minimum wire feed speed, the motor of the push-pull unit does not deliver
any actual rotational speed value.
Remedy:
Repeat the push-pull calibration. If the error message re-appears: Contact Af
-
ter-Sales Service.
St2 | E 10
Cause:
At minimum wire feed speed, the motor current of the wire-feed unit motor is
outside the permitted range. Possible reasons are disengaged wire-feed unit
motors or wire feed problems.
Remedy:
Engage the drive units of both wire-feed unit motors, arrange the hosepack in
as straight a line as possible; check the inner liner for kinks or soiling; check
the contact pressure on the 2-roller or 4-roller drive of the push-pull unit. Re
-
peat the push-pull calibration. If the error message re-appears: Contact After-
Sales Service.
St2 | E 11
Cause:
At minimum wire feed speed, the motor current of the push-pull unit is outside
the permitted range. Possible reasons are disengaged wire-feed unit motors
or wire feed problems.
Remedy:
Engage the drive units of both wire-feed unit motors, arrange the hosepack in
as straight a line as possible; check the inner liner for kinks or soiling; check
the contact pressure on the 2-roller or 4-roller drive of the push-pull unit. Re
-
peat the push-pull calibration. If the error message re-appears: Contact After-
Sales Service.
Summary of Contents for KD 7000 D-11
Page 2: ...2...
Page 4: ...4...
Page 29: ...29 EN 1 2 1 2...
Page 33: ...33 EN 1 2 PVC 1 4 3 PVC KLEBER GLUE COLLE...
Page 45: ...45 EN...
Page 46: ...46...
Page 47: ...47 EN...