Service codes
shown when the
drive units are
disengaged
(open-circuit cali
-
bration)
Err | Eto
Cause:
Incorrect measurement during push-pull calibration
Remedy:
Repeat push-pull calibration
St1 | E 1
Cause:
At minimum wire feed speed, the wire-feed unit motor does not deliver any ac
-
tual rotational speed value.
Remedy:
Repeat the push-pull calibration. If the error message re-appears: Contact Af
-
ter-Sales Service.
St1 | E 2
Cause:
At maximum wire feed speed, the wire-feed motor does not deliver any actual
rotational speed value.
Remedy:
Repeat the push-pull calibration. If the error message re-appears: Contact Af
-
ter-Sales Service.
St1 | E 3
Cause:
At minimum wire feed speed, the wire-feed unit motor does not deliver any ac
-
tual rotational speed value.
Remedy:
Repeat the push-pull calibration. If the error message re-appears: Contact Af
-
ter-Sales Service.
St1 | E 4
Cause:
At minimum wire feed speed, the wire-feed unit motor does not deliver any ac
-
tual rotational speed value.
Remedy:
Repeat the push-pull calibration. If the error message re-appears: Contact Af
-
ter-Sales Service.