6
Select “
Update via LAN
”
7
Enter the IP address of the PC/laptop
8
Click on the “
Run update
” button
The confirmation prompt for the update appears.
9
Click on the “
Yes
” button
The update starts and the progress is displayed as a bar and a percentage.
10
Once the update has been carried out successfully, click on the “
Apply/Save
”
button
The update is complete when the “Supply LED” lights up green again.
If the connection to the server fails:
-
Deactivate the firewall for the duration of the update
-
Retry the update
62