5
Controls, Con-
nections and
Indicators
(continued)
No. Function
(7) IP address switch
used to switch from an assigned IP address to a default IP address ‘169.254.0.180’
Assigned IP:
‘Fronius Datalogger Web’ operates using an assigned IP address
(factory setting 192.168.1.180). The IP address can be set at the
‘Fronius Datalogger Web’ website
169.254.0.180:
‘Fronius Datalogger Web’ operates using a fixed IP address
169.254.0.180
The fixed IP address is used for a direct connection to a PC
without having to pre-configure the PC
(8) LAN connection
Ethernet interface colored in blue for connecting an Ethernet cable
(9) External power supply connection
for connecting an external power source when the power within ‘Fronius Solar Net’
is insufficient (e.g. when too many DATCOM components are installed in ‘Fronius
Solar Net’).
Important!
The external power supply unit for the Fronius Datalogger Web must
have a secure disconnect between components supplying mains voltage (SELV or
Class 2 for USA / Canada).
The output of the power supply unit may not exceed a
max. of 15 VA / 1.25 A.
If the power supply is sufficient, the Supply LED lights up green (2).
(10) Solar Net IN connection
‘Fronius Solar Net’ input colored red for connecting other DATCOM component (e.g.
inverters, sensor cards, etc.)
(11) Solar Net OUT connection
‘Fronius Solar Net’ output colored red for connecting other DATCOM component
(e.g. inverters, sensor cards, etc.)