87
EN
Class 3 status
codes
Class 3 includes status codes that may occur while feeding energy into the grid, but gen-
erally do not cause the process to be interrupted for any length of time.
The inverter disconnects automatically from the grid, the grid is then monitored as specified
and the inverter attempts to resume feeding energy into the grid.
301
Overcurrent (AC)
Behaviour
Short-term interruption while feeding energy into the grid due to
overcurrent in the alternating current circuit
The inverter resumes with its startup routine.
Remedy
Fault is rectified automatically
If this status code keeps recurring, contact your system engi-
neer
303
Power module overtemperature
Behaviour
Short-term interruption while feeding energy into the grid due to
overtemperature
The inverter resumes with its startup routine.
Remedy
Purge cooling air openings and heat sink if necessary;
fault is rectified automatically
If this status code keeps recurring, contact your system engi-
neer
304
Internal temperature too high
Behaviour
Short-term interruption while feeding energy into the grid due to
overtemperature
The inverter resumes with its startup routine
Remedy
Purge cooling air openings and heat sink if necessary;
fault is rectified automatically
If this status code keeps recurring, contact your system engi-
neer
305
If the grid relay is closed, no energy is transferred to the grid
Behaviour
Permanent interruption while feeding energy into the grid
Remedy
If this status code keeps recurring, contact your system engi-
neer
307 (DC low)
DC input voltage too low for feeding energy into the grid
Behaviour
Short-term interruption while feeding energy into the grid
The inverter resumes with its startup routine.
Summary of Contents for Agilo 100.0-3
Page 2: ...0...
Page 4: ...2...
Page 8: ...6...
Page 13: ...General information...
Page 14: ......
Page 30: ...28...
Page 31: ...Installation and commissioning...
Page 32: ......
Page 51: ...49 EN 1 2 Inserting the fuse grounds the solar modules on the negative pole 1 1 1 2 2...
Page 53: ...51 EN 2 3 Tightening torque 3 Nm 1 3 2 4 5 4 3 2 4 5 1 5...
Page 57: ...Operation...
Page 58: ......
Page 84: ...82...
Page 85: ...Troubleshooting and maintenance...
Page 86: ......
Page 107: ...Appendix...
Page 108: ......