Setting the address
Safety
General
The Fronius Solar Net allows up to 200 Fronius String Control 250/30 DCD DF units to be
used at the same time. Addresses are assigned to distinguish between individual Fronius
String Controls.
Use the address selector to set addresses 0 - 199:
(1)
Jumper for the hundredths
(2)
Wheel for the tens
(3)
Wheel for the ones
Setting the ad-
dress - examples
WARNING!
An electric shock can be fatal. Danger from DC voltage in PV mod-
ules.
-
Make sure that both the input side and output side of the device are de-ener-
gised before attaching any connections.
-
All connections must be made by qualified electricians.
-
Note the safety rules in these operating instructions.
(2)
(3)
1XX
0XX
(1)
Fronius String Control 250/30 DCD DF
No. 1
Fronius String Control 250/30 DCD DF
No. 37
Fronius String Control 250/30 DCD DF
No. 123
0XX
1XX
0
1
0
0XX
1XX
3
7
0
0XX
1XX
2
3
1