ALARMS
E1:
NO PALLET DETECTED 1x beep than pause (repeated sequence)
E2:
EMERGENCY SWITCH
2x beep than pause (repeated sequence)
E3:
INVERTER ERROR
3x beep than pause (repeated sequence)
E4:
SAFETY BELT
4x beep than pause (repeated sequence)
E5:
BASE SAFETY DEVICE
5x beep than pause (repeated sequence)
ES:
SERVICE BY FROMM ENGINEER REQUESTED
ALARM RESET
After having cleared the fault, push the
RESET
button
E1 - NO PALLET DETECT
Problem suggestion
Possible solution
- Pallet is not recognized by photo electric cell
- Dark goods? Replace sensor by sensor
suitable for dark goods. (N5.2638)
- Pallet to be wrapped is lower that 600mm.
Ask FROMM engineer to change parameter
PA04 to 0 (OFF)
- Photocell (
Fig. 1
) not connected properly
- Check the wiring / connector
- Photocell malfunction
- Replace the photocell
- Check LED L22 (1) (
Fig. 3
) (Load on
turntable LED is ON)
Fig. 1
Fig. 2
Fig. 3
Should the problem persist, contact the Customer After-Sales Service of MANUFACTURER
E2 - MAIN CONTACTOR / EMERGENCY SWITCH
Problem suggestion
Possible solution
- After switching on the machine E2 appears in the
display
-
Press the RESET button. Inverters
are activated again.
- This alarm signals that the emergency button
was pressed
-
Check the situation and deactivate
the mushroom-head button
- Emergency button not working or properly
connected
-
Replace the emergency button
-
Check LED L23 (Emergency NOT
pressed LED standard is ON)
Should the problem persist, contact the Customer After-Sales Service of MANUFACTURER